Paradyne 4200 manual 14-10, 9. INH-MSG-ALL Response Parameters, INH-MSG-ALLTAMPAALL40MN, Example

Models: 4200

1 382
Download 382 pages 39.36 Kb
Page 272
Image 272
Table 14-9. INH-MSG-ALL Response Parameters

14. System Commands

Table 14-9. INH-MSG-ALL Response Parameters

Parameter

Explanation

 

 

sid

Source NE identification

 

 

yy-mm-dd

Year, month, and day

 

 

hh:mm:ss

Hour, minute, and second

 

 

M

Message generated in response to an input command

 

 

c

If provided, ctag; otherwise 0

 

 

COMPLD

Completed

 

 

DENY

Input command is denied

 

 

/* */

Enclosed are human readable comments – unspecified format

 

 

errcde

Error code (see Appendix A, Error Codes)

 

 

Example

Inhibit the reporting of Minor and Not Alarmed autonomous messages.

INH-MSG-ALL:TAMPA:ALL:40::MN;

TAMPA 01-06-24 11:30:43

M40 COMPLD

/* INH-MSG-ALL:TAMPA:ALL:40::MN */

;

Related Command

ALW-MSG-ALLon page 14-4

14-10

August 2002

4200-A2-GB20-00

Page 272
Image 272
Paradyne 4200 manual 14-10, 9. INH-MSG-ALL Response Parameters, INH-MSG-ALLTAMPAALL40MN TAMPA 01-06-24 M 40 COMPLD, Example