Paradyne 4200 manual Set-Dat, 14-29, 23. SET-DAT Command Parameters, SET-DATtidctagdate,time, IP c

Models: 4200

1 382
Download 382 pages 39.36 Kb
Page 291
Image 291
SET-DAT

14. System Commands

SET-DAT

The SET-DAT command sets the date and time in an NE.

Table 14-23. SET-DAT Command Parameters

SET-DAT:[tid]::[ctag]::date,time;

RESTRICTIONS: All parameters in this command are position-defined. Resetting the unit will also reset the date and time.

[tid]

The identification of the target NE. TID is optional and has a default

 

value of null. The NE's SID code is the only other valid value.

 

 

[ctag]

The correlation tag that correlates an input command with its associated

 

output response(s). It is assigned by the originator of the command. The

 

value is limited to six characters, which may be an identifier or a decimal

 

numeral. It is optional with a default of 0.

 

 

date

Date in the format mm-dd-yy:

Where:

mm = 112

dd = 131

yy = 099

time

Time in the format hh-mm-ss:

Where:

hh = 023

mm = 059

ss = 059

Response Format

If, in less than 2 seconds, a normal or error response cannot be sent, the following acknowledgment response will be sent:

IP c

After the above response, a new command input may be generated.

Normal Response:

sid yy-mm-dd hh:mm:ss

Mc COMPLD

/* SET-DAT:[tid]::[ctag]::date,time */;

Error Response:

sid yy-mm-dd hh:mm:ss M c DENY

/* SET-DAT:[tid]::[ctag]::date,time */; errcde

;

4200-A2-GB20-00

August 2002

14-29

Page 291
Image 291
Paradyne 4200 manual Set-Dat, 14-29, 23. SET-DAT Command Parameters, SET-DATtidctagdate,time, Response Format, IP c