Paradyne 4200 manual Ent-Crs-Vc, 5. ENT-CRS-VC Command Parameters, ENT-CRS-VCtidntvcl,ltvclctagpst

Models: 4200

1 382
Download 382 pages 39.36 Kb
Page 141
Image 141
ENT-CRS-VC

6. Cross Connect Commands

ENT-CRS-VC

The ENT-CRS-VC command establishes a VC-level cross-connection between the NT and LT.

Table 6-5. ENT-CRS-VC Command Parameters

ENT-CRS-VC:[tid]:nt_vcl,lt_vcl:[ctag]::::[pst];

RESTRICTIONS: All parameters in this command are position-defined. The range of values for vpi and vci is determined by the number of VPI and VCI bits allocated. View the number of bits allocated with the RTRV-PROFILE-ATMACCcommand.

[tid]

Identification of the target NE. The default value is null. The NE SID

 

code is the only other valid value.

 

 

nt_vcl

Virtual Channel Identifier for the Virtual Channel Link on the NT

 

(network) side. Enter in the following format, replacing lower-case

 

parameters with the values given:

 

NTVCL-vpi-vci

 

– vpi: Virtual Path Identifier (for LT vpi=0, for NT vpi=015)

 

– vci: Virtual Channel Identifier for the Virtual Channel Link (for LT

 

vpi=3263, for NT vpi=321023)

 

Grouping is allowed for up to 8 AIDs. Ranging is allowed.

 

 

lt_vcl

Virtual Channel Identifier for the Virtual Channel Link on the LT (user)

 

side. Enter in the following format, replacing lower-case parameters with

 

the values given:

 

LTVCL-rack-shelf-slot-circuit-vpi-vci: Virtual Channel in the NT

 

– rack: Rack number (1)

 

– shelf: Shelf number (1)

 

– slot: LT slot number (1)

 

– circuit: ADSL circuit on the LT (124)

 

– vpi: Virtual Path Identifier (for LT vpi=0, for NT vpi=015)

 

– vci: Virtual Channel Identifier (for LT vpi=3263,

 

for NT vpi=321023)

 

Grouping and ranging are allowed. If these features are used, the two

 

sets of AIDs must match one-to-one.

 

 

[ctag]

Correlation tag (6 characters maximum) that links an input command

 

with associated output responses. The default is 0.

 

 

[pst]

Desired Primary State. Valid values are:

 

IS: In-Service (default)

 

OOS: Out-Of-Service (OOS-MA is implied)

 

If no value is specified, IS is assumed.