RLS-LPBK-T1

15. Test Commands

RLS-LPBK-T1

The RLS-LPBK-T1 command releases any loopback currently active at the near end of a specific T1 facility, including configured loopbacks (set with the command OPR-LPBK-T1on page 15-2)and inband loopbacks (set with DS1 inband loopback codes).

Table 15-5. RLS-LPBK-T1 Command Parameters

RLS-LPBK-T1:[tid]:aid_ds1:[ctag][:];

RESTRICTIONS:

TAll parameters in this command are position-defined. Port loopbacks are supported only on LT ports.

[tid]

Identification of the target NE. The default value is null. The NE SID

 

code is the only other valid value.

 

 

aid_ds1

Access Identifier for the T1 facility. The value can be preceded with

 

AID=, but this is not required. Enter in the following format, replacing

 

lower-case parameters with the values given:

 

NTT1-circuit

 

– circuit: DS1 circuit on the NT (1)

 

 

[ctag]

Correlation tag (6 characters maximum) that links an input command

 

with associated output responses. The default is 0.

Response Format

If, in less than 2 seconds, a normal or error response cannot be sent, the following acknowledgment response is sent:

IP c

After the above response, a new command input may be generated.

Normal Response:

sid yy-mm-dd hh:mm:ss

Mc COMPLD

/* RLS-LPBK-T1:[tid]:aid_ds1:[ctag][:] */

;

Error Response:

sid yy-mm-dd hh:mm:ss M c DENY

/* RLS-LPBK-T1:[tid]:aid_ds1:[ctag][:] */ aid:ERRCDE=errcde

/* error description */

;

4200-A2-GB20-00

August 2002

15-7