Paradyne 4200 manual Opr-Lpbk-Vcl, 15-4, 3. OPR-LPBK-VCL Command Parameters

Models: 4200

1 382
Download 382 pages 39.36 Kb
Page 302
Image 302
OPR-LPBK-VCL

15. Test Commands

OPR-LPBK-VCL

The OPR-LPBK-VCL command places a specific Virtual Channel Link (VCL) in loopback mode.

Table 15-3. OPR-LPBK-VCL Command Parameters

OPR-LPBK-VCL:[tid]:aid_vcl:[ctag]:[locn],[orgn] [lpbktype];

RESTRICTIONS:

TAll parameters in this command are position-defined. Only one loopback at a time is allowed on a facility.

[tid]

Identification of the target NE. The default value is null. The NE SID

 

code is the only other valid value.

 

 

aid_vcl

Virtual channel identifier for OAM loopbacks. The value can be

 

preceded with AID=, but this is not required. Grouping and ranging are

 

allowed. Enter in the following format, replacing lower-case parameters

 

with the values given:

 

NTVCL-vpi-vci: VCL for NT circuit

 

LTVCL-rack-shelf-slot-circuit-vpi-vci: VCL for LT circuit

 

– rack: rack number (1)

 

– shelf: shelf number (1)

 

– slot: LT slot number (1)

 

– circuit: ADSL circuit on the LT (124)

 

– vpi: Virtual Path Identifier

 

– vci: Virtual Channel Identifier

 

– segment: ATM location identifier. A 32-character hexadecimal

 

field that identifies the intermediate point responsible for looping

 

back F5 OAM segment loopback cells. If absent, the loopback is

 

performed at the end of the segment connection. Not accepted for

 

lpbktype E2E. Optional for lpbktype SEG.

 

 

[locn]

Facility location. Valid values are:

 

FEND (far end): This is the default.

 

FEND_segment

 

 

[orgn]

Source of the signal to be looped back. The only valid value is NEND

 

(near end).

 

 

[ctag]

Correlation tag (6 characters maximum) that links an input command

 

with associated output responses. The default is 0.

 

 

[lpbktype]

Loopback type. Valid values are:

 

E2E: End-to-End loopback. Identifies an OAM loopback test on a VCL

 

or VCC termination point using an end-to-end OAM cell.

 

SEG: Segment loopback. Identifies an OAM loopback test on a VCL or

 

VCC termination point using a segment OAM cell (default).

15-4

August 2002

4200-A2-GB20-00

Page 302
Image 302
Paradyne 4200 manual Opr-Lpbk-Vcl, 15-4, 3. OPR-LPBK-VCL Command Parameters, OPR-LPBK-VCLtidaidvclctaglocn,orgn lpbktype