Table 13-6. RTRV-SYNCN Response Parameters

13. Synchronization Commands

Table 13-6. RTRV-SYNCN Response Parameters

Parameter

Explanation

 

 

tid

Target NE identification

 

 

yy-mm-dd

Year, month, and day

 

 

hh:mm:ss

Hour, minute, and second

 

 

M

Message generated in response to an input command

 

 

c

If provided, ctag; otherwise 0

 

 

COMPLD

Completed

 

 

DENY

Input command is denied

 

 

/* */

Enclosed are human readable comments – unspecified format

 

 

errcde

Error code (see Appendix A, Error Codes)

 

 

aid_syncn

As described for command parameters

 

 

syncn_nblk

Named parameter block for SYNCN. The block consists of the

 

parameter PRICREF (primary local refernce source for synchronizing

 

the clock), followed by an equal sign (=) and one of the following values:

 

LOOP = Loop timing recovered form the network-side facility

 

LOCAL = Local oscillator on NT board

 

 

Example

Retrieve the configuration of the reference source for synchronization of the NE clock.

RTRV-SYNCN:TAMPA:CLKSRCNT:42;

TAMPA 01-12-20 11:20:34

M42 COMPLD

/* RTRV-SYNCN:TAMPA:CLKSRCNT:42 */

CLKSRCNT::PRICREF=LOCAL;