Paradyne 4200 manual Rtrv-Alm-Eqpt, 10-9, 5. RTRV-ALM-EQPT Command Parameters

Models: 4200

1 382
Download 382 pages 39.36 Kb
Page 201
Image 201
RTRV-ALM-EQPT

10. Fault Commands

RTRV-ALM-EQPT

The RTRV-ALM-EQPT command retrieves current alarms for specified equipment.

Table 10-5. RTRV-ALM-EQPT Command Parameters

RTRV-ALM-EQPT:[tid]:aid_eqpts:[ctag]::[ntfcde],,[srveff];

RESTRICTIONS: All parameters in this command are position-defined.

[tid]

The identification of the target NE. TID is optional and has a default

 

value of null. The NE's SID code is the only other valid value.

 

 

aid_eqpts

Access identifier for the equipment. Each AID format can be preceded

 

with AID=, but this is not required. Enter in the following format,

 

replacing lower-case parameters with the values given:

 

LT-rack-shelf-slot: All LT units

 

LTA-rack-shelf-slot: LTA units

 

SHELF-rack-shelf: shelf

 

rack: Rack Number (1)

 

shelf: Shelf Number (1)

 

slot: LT Slot Number (1)

 

Grouping is allowed. ALL may be used.

 

 

[ctag]

The correlation tag that links an input command with its associated

 

output responses. It is assigned by the originator of the command. The

 

value is limited to six characters, which may be an identifier or a decimal

 

numeral. It is optional with a default of 0.

 

 

[ntfncde]

Notification code. Valid values are:

 

CR: Critical alarm

 

MJ: Major alarm

 

MN: Minor alarm

 

Grouping is allowed. If no value is specified, ALL is assumed.

 

 

[serveff]

Service effect. Valid values are:

 

SA: Service affecting

 

NSA: Not service affecting

 

Grouping is allowed. If no value is specified, ALL is assumed.

4200-A2-GB20-00

August 2002

10-9

Page 201
Image 201
Paradyne 4200 manual Rtrv-Alm-Eqpt, 10-9, 5. RTRV-ALM-EQPT Command Parameters, RTRV-ALM-EQPTtidaideqptsctagntfcde,,srveff