RTRV-T1

4. DS1 Facility Commands

RTRV-T1

The RTRV-T1 command retrieves the configuration data associated with a DS-1 facility.

Table 4-12. RTRV-T1 Command Parameters

RTRV-T1:[tid]:aid_ds1:[ctag]::::[pstf],[sstf];

Restrictions: All parameters in this command are position-defined.

[tid]

Identification of the target NE. They default value is null. The NE SID

 

code is the only other valid value.

 

 

aid_ds1

Access Identifier for the DS1 facility. The value can be preceded with

 

AID=, but this is not required. Grouping and ranging are allowed. Enter

 

in the following format, replacing lower-case parameters with the values

 

given:

 

NTT1-circuit

 

– circuit: DS1 circuit on the NT (1)

 

 

[ctag]

Correlation tag (1...6 characters) that links an input command with

 

associated output responses. The default is 0.

 

 

[pstf]

Primary state filter. Valid values are:

 

IS: Matches IS-NR

 

OOS: Out of service. Matches OOS-MA (out of service, management),

 

OOS-AU (out of service, autonomous), OOS-AUMA (out of service,

 

autonomous and management)

 

AU: Autonomous. Matches OOS-AU, OOS-AUMA

 

MA: Management. Matches OOS-MA, OOS-AUMA

 

If no value is specified, this filter is ignored.

 

 

[sstf]

Secondary state filter. The value is:

 

LPBK: Retrieve looped-back entities only

 

If no value is specified, this filter is ignored.

Response Format

If, in less than 2 seconds, a normal or error response cannot be sent, the following acknowledgment response is sent:

IP c

After the above response, a new command input may be generated.