STP-LAMPTST

15. Test Commands

STP-LAMPTST

The STP-LAMPTST command stops a lamp (LED) test on a device.

Table 15-11. STP-LAMPTST Command Parameters

STP-LAMPTST:[tid]:aid_eqpt:[ctag];

RESTRICTION: All parameters in this command are position-defined.

[tid]

Identification of the target NE. The default value is null. The NE SID

 

code is the only other valid value.

 

 

aid_eqpt

Equipment access identifier. The value can be preceded with AID=, but

 

this is not required. Grouping and ranging are allowed. Enter in the

 

following format, replacing lower-case parameters with the values

 

given:

 

COM: Common equipment system identifier.

 

Grouping and ranging are not allowed.

 

 

[ctag]

Correlation tag (6 characters maximum) that links an input command

 

with associated output responses. The default is 0.

Response Format

If, in less than 2 seconds, a normal or error response cannot be sent, the following acknowledgment response is sent:

IP c

After the above response, a new command input may be generated.

Normal Response:

sid yy-mm-dd hh:mm:ss

Mc COMPLD

/* STP-LAMPTST:[tid]:aid_eqpt:[ctag][:] */

;

Error Response:

sid yy-mm-dd hh:mm:ss M c DENY

/* STP-LAMPTST:[tid]:aid_eqpt:[ctag][:] */ aid_eqpt:ERRCDE=errcde

/* error description */

;

4200-A2-GB20-00

August 2002

15-13