Paradyne 4200 manual 6. ED-IPPORT Response Parameters, DLT-ATMARPENT on page ENT-ATMARPENT on page

Models: 4200

1 382
Download 382 pages 39.36 Kb
Page 166
Image 166
Table 8-6. ED-IPPORT Response Parameters

8. IP Access Commands

Table 8-6. ED-IPPORT Response Parameters

Parameter

Explanation

 

 

tid

Target NE identification

 

 

yy-mm-dd

Year, month, and day

 

 

hh:mm:ss

Hour, minute, and second

 

 

M

Message generated in response to an input command

 

 

c

If provided, ctag; otherwise 0

 

 

COMPLD

Completed

 

 

DENY

Input command is denied

 

 

/* */

Enclosed are human readable comments – unspecified format

 

 

errcde

Error code (see Appendix A, Error Codes)

 

 

Example

Configure the SLIP port with a configuration mode of BOOTP and a physical address of 18-00-42-49-09-03-27-22.

ED-IPPORT:TAMPA:SLIP:42::BOOTP:PHYADDR="18-00-42-49-09-03-27 -22";

TAMPA 01-11-24 12:30:43 M 42 COMPLD

/* ED-IPPORT:TAMPA:SLIP:42::BOOTP:PHYADDR="18-00-42-49-09-03-27 -22" */

;

Related Commands

DLT-ATMARPENTon page 8-2

ENT-ATMARPENTon page 8-9

ENT-IPPORTon page 8-11

RTRV-IPPORTon page 8-19

8-8

August 2002

4200-A2-GB20-00

Page 166
Image 166
Paradyne 4200 6. ED-IPPORT Response Parameters, ED-IPPORTTAMPASLIP42BOOTPPHYADDR=18-00-42-49-09-03-27, RTRV-IPPORT on page