Table 4-3. ENT-T1 Command Parameters (2 of 2)

4. DS1 Facility Commands

Table 4-3. ENT-T1 Command Parameters (2 of 2)

ENT-T1:[tid]:aid_ds1:[ctag]:::ds1_nblk:[pst];

ds1_nblk

For the following parameters if no value is specified, null is assumed.

(continued)

ATMACCPROF: ATM Access Profile index (1). This value determines

 

the range of values for vpi and vci in several other commands. The

 

value cannot be changed while any VPLs or VCLs exist.

 

ATMACCPROFNM: ATM Access Profile name. The default is NT

 

DEFVAL.

 

QOSCLASS: Quality of service of connections on this port. The valid

 

 

[pst]

Desired state. Valid values are:

 

IS: In service (default)

 

OOS: Out of service. OOS-MA (out of service, management) is implied.

 

If no value is specified, this parameter is set to IS.

Table 4-4. T1 Line Equalization Values

EQLZ value

Cable length (feet)

Equalization (dB)

 

 

 

0 (default)

0133

0.6

 

 

 

200

134266

1.2

 

 

 

300

267399

1.8

 

 

 

500

400533

2.4

 

 

 

600

534655

3.0

 

 

 

Response Format

If, in less than 2 seconds, a normal or error response cannot be sent, the following acknowledgment response is sent:

IP c

After the above response, a new command input may be generated.

Normal Response

sid yy-mm-dd hh:mm:ss

Mc COMPLD

/* ENT-T1:[tid]:aid_ds1:[ctag]:::ds1_nblk:[pst] */

;