Paradyne 4200 5-14, sid yy-mm-dd hhmmss M c DENY RTRV-ATMPORTtidaidatmportctagpstfsstf, errcde

Models: 4200

1 382
Download 382 pages 39.36 Kb
Page 124
Image 124
sid yy-mm-dd hh:mm:ss M c DENY

5. ATM Commands

Error Response:

sid yy-mm-dd hh:mm:ss M c DENY

/* RTRV-ATMPORT:[tid]:aid_atmport:[ctag]::::[pstf][sstf]

*/

errcde

;

Table 5-12. RTRV-ATMPORT Response Parameters

Parameter

Explanation

 

 

tid

Target NE identification

 

 

yy-mm-dd

Year, month, and day

 

 

hh:mm:ss

Hour, minute, and second

 

 

M

Message generated in response to an input command

 

 

c

If provided, ctag; otherwise 0

 

 

COMPLD

Completed

 

 

DENY

Input command is denied

 

 

/* */

Enclosed are human readable comments – unspecified format

 

 

errcde

Error code (see Appendix A, Error Codes)

 

 

aid_atmport

As described for command parameters (see Table 5-11,

 

RTRV-ATMPORT Command Parameters).

 

 

state

State from the Bellcore model. Values are:

 

IS-NR. In service, normal.

 

OOS-AU: Out of service, autonomous.

 

OOS-MA: Out of service, management. Transient state (changes to

 

OOS-AUMA).

 

OOS-AUMA: Out of service, autonomous and management.

 

 

sstf

As described for command parameters (see Table 5-11,

 

RTRV-ATMPORT Command Parameters).

 

 

atmport_nblk

SEGID: ATM segment location ID. A 16-octet field that identifies this

 

ATM interface for OAM F5 loopbacks. When a segment F5 OAM

 

loopback cell is received, the destination segment location in the cell is

 

compared to the segment location ID for the card. If the destination

 

location ID matches the location ID or is all ones, the cell is looped back

 

to the source. If there is not a match, the cell passes through the card.

 

he value is entered as 32 hexadecimal characters or ALLONES

 

(default). Allowed values are restricted per ITU-T1.610 as follows:

 

The first byte must be 01, 02, 03, FF or 6A.

 

TIf the first octet is FF, then octets 216 must also be FF.

 

If the first octet is 6A, then octets 216 must also be 6A.

 

If no value is specified for this field, then this parameter remains the

 

same.

 

 

5-14

August 2002

4200-A2-GB20-00

Page 124
Image 124
Paradyne 4200 5-14, sid yy-mm-dd hhmmss M c DENY RTRV-ATMPORTtidaidatmportctagpstfsstf, Error Response, errcde, Parameter