RD-SYNCN

13. Synchronization Commands

RD-SYNCN

The RD-SYNCN Command retrieves the current reference source for synchronization of the NE clock.

Table 13-3. RD-SYNCN Command Parameters

RD-SYNCN:[tid]:[aid_syncn]:[ctag][:];

Restrictions: All parameters in this command are position-defined.

[tid]

Identification of the target NE. The default value is null. The NE SID

 

code is the only other valid value.

 

 

[aid_syncn]

AID of the NE clock. The value is CLKSRCNT.

 

 

[ctag]

Correlation tag (6 characters maximum) that links an input command

 

with associated output responses. The default is 0.

Response Format

If, in less than 2 seconds, a normal or error response cannot be sent, the following acknowledgment response is sent:

IP c

After the above response, a new command input may be generated.

Normal Response:

sid yy-mm-dd hh:mm:ss

Mc COMPLD

/* RD-SYNCN:[tid]:aid_syncn:[ctag][:] aid_syncn,cref */

;

Error Response:

sid yy-mm-dd hh:mm:ss M c DENY

/* RD-SYNCN:[tid]:aid_syncn:[ctag][:] */ aid:ERRCDE=errcde

/* error description */

;

13-4