ED-SYNCN

13. Synchronization Commands

ED-SYNCN

The ED-SYNCN Command configures the reference source for synchronization of the NE clock.

Table 13-1. ED-SYNCN Command Parameters

ED-SYNCN:[tid]:[aid_syncn]:[ctag]:::[syncn_nblk];

Restrictions: All parameters in this command are position-defined.

[tid]

Identification of the target NE. The default value is null. The NE SID

 

code is the only other valid value.

 

 

[aid_syncn]

AID of the NE clock. The value is CLKSRCNT.

 

 

[ctag]

Correlation tag (6 characters maximum) that links an input command

 

with associated output responses. The default is 0.

 

 

syncn_nblk

Named parameter block for SYNCN. The block consists of one or more

 

of the following parameters, in any order separated by commas, each

 

followed by an equal sign and a valid value. If not specified, the value of

 

this parameter remains unchanged.

PRICREF: Primary reference source for synchronizing the clock. Valid values are:

LOOP: Loop timing recovered from network side facility

LOCAL: Local oscillator on NT board

Response Format

If, in less than 2 seconds, a normal or error response cannot be sent, the following acknowledgment response is sent:

IP c

After the above response, a new command input may be generated.

Normal Response:

sid yy-mm-dd hh:mm:ss

Mc COMPLD

/* ED-SYNCN:[tid]:[aid_syncn]:[ctag]:::[syncn_nblk] */

;

Error Response:

sid yy-mm-dd hh:mm:ss M c DENY

/* ED-SYNCN:[tid]:[aid_syncn]:[ctag]:::[syncn_nblk] */ aid:ERRCDE=errcde

/* error description */

;

13-2

August 2002

4200-A2-GB20-00

Page 256
Image 256