Table 4-9. REPT-OPSTAT-T1 Response Parameters

4. DS1 Facility Commands

Table 4-9. REPT-OPSTAT-T1 Response Parameters

Parameter

Explanation

 

 

tid

Target NE identification

 

 

yy-mm-dd

Year, month, and day

 

 

hh:mm:ss

Hour, minute, and second

 

 

M

Message generated in response to an input command

 

 

c

If provided, ctag; otherwise 0

 

 

COMPLD

Completed

 

 

DENY

Input command is denied

 

 

/* */

Enclosed are human readable comments – unspecified format

 

 

errcde

Error code (see Appendix A, Error Codes)

 

 

aid_ds1

As described for command parameters (see Table 4-8,REPT-OPSTAT-

 

T1 Command Parameters).

 

 

op_ds1

DS1 operational parameter. Values are:

 

INCELLS: Rolling count of cells received on this facility.

 

OUTCELLS: Rolling count of cells transmitted on this facility and

 

discarded for any reason.

 

INCELLSUKN: Rolling count of cells received on this facility and

 

discarded during header validation with unrecognized VPI/VCI values.

 

OCD: Rolling count of Out of Cell Delineation events on this facility.

 

STATUSCD: Current status of cell delineation state. Values are:

 

– Normal: No failure condition

 

– LOCD: Loss Of Cell Delineation

 

 

value

Value of parameter specified by op_ds1.

 

 

Example

Report DS1 facility operational parameters for NTT1-3.

REPT-OPSTAT-T1:TAMPA:NTT1-1;

TAMPA 01-11-24 12:30:43

M42 COMPLD

/* REPT-OPSTAT-T1:TAMPA:NTT1-1:42 */

"NTT1-3:INCELLS,35500" "NTT1-3:OUTCELLS,23300"

;

Related Commands

None

4200-A2-GB20-00

August 2002

4-11

Page 103
Image 103
Paradyne 4200 4-11, 9. REPT-OPSTAT-T1 Response Parameters, REPT-OPSTAT-T1TAMPANTT1-1 TAMPA 01-11-24 M 42 COMPLD, Example