Paradyne 4200 manual 6. REPT ALM T1 Response Parameters

Models: 4200

1 382
Download 382 pages 39.36 Kb
Page 100
Image 100
REPT ALM T1

4. DS1 Facility Commands

REPT ALM T1

The REPT ALM T1 message reports current T1 (DS1) facility alarms from the NE.

Table 4-6. REPT ALM T1 Response Parameters

almcode atag REPT ALM T1 "aid_ds1:ntfncde,cond_ds1, serveff,[ocrdat],[ocrtm],[locn],[dirn]:[cond_descr]";

almcde

Alarm code. Identifies the severity of the alarm. Values are:

 

*C: Critical alarm

 

**: Major alarm

 

*^: Minor alarm

 

A^: Automatic message (typically used to report a cleared alarm)

 

 

atag

Automatic tag that indicates the numerical sequence of messages

 

reported.

 

 

aid_ds1

Access identifier for an environment. Values are:

 

NTT1-circuit

 

– circuit: DS1 circuit in the NT (1)

 

 

ntfncde

Notification code. Values are:

 

CR: Critical alarm

 

MJ: Major alarm

 

MN: Minor alarm

 

CL: Cleared alarm

 

 

cond_ds1

DS1 facility condition. Values are:

 

ACTLPBK: Facility placed in loopback

 

AIS: Alarm indication signal

 

LCD: Loss of ATM cell delineation

 

LOF: Loss of framing

 

LOS: Loss of signal/clock

 

RAI: Remote alarm indication

 

 

serveff

Service effect. Values are:

 

SA: Service affecting

 

NSA: Not service affecting

 

 

[ocrdat]

Date of occurrence in the format: mm-dd (month and day)

 

 

[ocrtm]

Time of occurrence in the format: hh-mm (hour 023 and minute 059)

 

 

[locn]

Location of condition. The value is NEND (Near End).

 

 

[dirn]

Direction of condition. Values are:

 

RCV: Receive

 

TRMT: Transmit (for ACTLPBK)

 

 

[cond_descr]

Description of alarm condition (40 characters maximum).

4-8

August 2002

4200-A2-GB20-00

Page 100
Image 100
Paradyne 4200 manual 6. REPT ALM T1 Response Parameters