Paradyne 4200 14-12, 11. INIT-SYS Response Parameters, Example, Related Commands, Explanation

Models: 4200

1 382
Download 382 pages 39.36 Kb
Page 274
Image 274
Table 14-11. INIT-SYS Response Parameters

14. System Commands

Table 14-11. INIT-SYS Response Parameters

Parameter

Explanation

 

 

sid

Source NE identification

 

 

yy-mm-dd

Year (last two digits), month, and day

 

 

hh:mm:ss

Hour, minute, and second

 

 

M

Message generated in response to an input command

 

 

c

If provided, ctag; otherwise 0

 

 

COMPLD

Completed

 

 

DENY

Input command is denied

 

 

/* */

Enclosed are human readable comments – unspecified format

 

 

errcde

Error code (see Appendix A, Error Codes)

 

 

Example

Perform a complete reset of the NTA unit.

INIT-SYS:TAMPA:NTA:40::3;

TAMPA 02-03-22 10:30:23

M40 COMPLD

/* INIT-SYS:TAMPA:NTA:40::3 */

;

Related Commands

None

14-12

August 2002

4200-A2-GB20-00

Page 274
Image 274
Paradyne 4200 14-12, 11. INIT-SYS Response Parameters, INIT-SYSTAMPANTA403 TAMPA 02-03-22 M 40 COMPLD INIT-SYSTAMPANTA403