Paradyne 4200 manual 10-19, 11. RTRV-ATTR-ALL Command Parameters 2 of, Response Format, IP c

Models: 4200

1 382
Download 382 pages 39.36 Kb
Page 211
Image 211
Table 10-11. RTRV-ATTR-ALL Command Parameters (2 of 2)

10. Fault Commands

Table 10-11. RTRV-ATTR-ALL Command Parameters (2 of 2)

RTRV-ATTR-ALL:[tid]:aid_all:[ctag]::[ntfcde],[cond_all], [locn],[dirn];

[cond_all]

DECRATE-F: Decreasing Rate (Fast channel). There is no

(continued)

corresponding standing condition clear message.

 

 

LPRS-L: Loss Of Power Seconds (Line) (far-end only)

 

LOSS-L: Loss of Signal Seconds (Line) (near-end only)

 

LOS: Loss Of Signal/clock

 

LPR: Loss Of Power

 

LORATE: Line rate is below planned rate (Loss of Signal Quality)

 

PROGVER: Failed to load or find requested software

 

RAI: Remote Alarm Indication

 

RMTDLFAIL: Failed to download software

 

SWROLLBACK: Software version rolled back

 

Grouping is allowed. If no value is specified, ALL is assumed.

 

 

[locn]

Location of the condition. Valid values are:

 

NEND: Near End

 

FEND: Far End

 

Only applicable to conditions supporting location. If no value is

 

specified, ALL is assumed.

 

 

[dirn]

Direction of the condition. Valid values (for conditions supporting

 

direction):

 

RCV: Receive

 

TRMT: Transmit

 

If no value is specified, ALL is assumed.

Response Format

If, in less than 2 seconds, a normal or error response cannot be sent, the following acknowledgment response will be sent:

IP c

After the above response, a new command input may be generated.

Normal Response:

sid yy-mm-dd hh:mm:ss

Mc COMPLD

/* RTRV-ATTR-ALL:[tid]:aid_all:[ctag]::[ntfncde],

[cond_all] */ "aid,aid_type:ntfncde,cond,[locn],[dirn]"

;

4200-A2-GB20-00

August 2002

10-19

Page 211
Image 211
Paradyne 4200 manual 10-19, 11. RTRV-ATTR-ALL Command Parameters 2 of, condall */ aid,aidtypentfncde,cond,locn,dirn, IP c