REPT ALM EQPT

7. Equipment Commands

REPT ALM EQPT

The REPT ALM EQPT message reports current alarms from the NE.

Table 7-3. REPT ALM EQPT Message Parameters

almcde atag REPT ALM EQPT aid_eqpts:ntfcde,cond_eqpt, srveff,[ocrdat],[ocrtm]: [conddescr];

almcde

Alarm code. Identifies the severity of the alarm. Values are:

*C: Critical alarm

**: Major alarm

*^: Minor alarm

A^: Automatic message (typically reports a cleared alarm)

atag

Automatic tag. Indicates the numerical sequence of reported messages.

 

 

aid_eqpts

Access identifier for the equipment. Each AID format can be preceded

 

with AID=, but this is not required. Enter in the following format,

 

replacing lower-case parameters with the values given:

 

LT-rack-shelf-slot: LT unit

 

SHELF-rack-shelf: shelf

 

– rack: Rack Number (1)

 

– shelf: Shelf Number (1)

 

– slot: LT Slot Number (1)

 

 

[ntfncde]

Notification code. Valid values are:

 

CR: Critical alarm

 

MJ: Major alarm

 

MN: Minor alarm

 

CL: Cleared alarm

 

 

cond_eqpt

Equipment condition. Valid values are:

 

– EQPT: Equipment failed self-test

 

FANALM-1: Fan alarm for fan 1

 

FANALM-2: Fan alarm for fan 2

 

– PROGVER: Failed to load or find requested software

 

– RMTDLFAIL: Failed to download software

 

– SWROLLBACK: Software version rolled back

 

 

[serveff]

Service effect. Valid values are:

 

SA: Service affecting

 

– NSA: Not service affecting

 

 

[ocrdat]

Date of alarm occurrence in the format mm-dd (month-day).

 

 

[ocrtm]

Time of alarm occurrence in the format hh-mm (hour-minute).

 

 

[conddescr]

Description of alarm condition (40 characters maximum).