Table 15-12. STP-LAMPTST Response Parameters

15. Test Commands

Table 15-12. STP-LAMPTST Response Parameters

Parameter

Explanation

 

 

sid

Source NE identification

 

 

yy-mm-dd

Year, month, and day

 

 

hh:mm:ss

Hour, minute, and second

 

 

M

Message generated in response to an input command

 

 

c

If provided, ctag; otherwise 0

 

 

COMPLD

Completed

 

 

DENY

Input command is denied

 

 

/* */

Enclosed are human readable comments – unspecified format

 

 

errcde

Error code (see Appendix A, Error Codes)

 

 

aid_eqpt

Equipment access identifier. The value can be preceded with AID=, but

 

this is not required. Grouping and ranging are allowed. Enter in the

 

following format, replacing lower-case parameters with the values

 

given:

 

COM: Common equipment system identifier.

 

Grouping and ranging are not allowed.

 

 

Example

Stop a lamp test on the TAMPA device.

STP-LAMPTST:TAMPA:COM;

TAMPA 01-11-24 12:30:43

M40 COMPLD

/* STP-LAMPTST:TAMPA:COM */

;

Related Command

STA-LAMPTSTon page 15-11