Paradyne 4200 Ed-Eqpt, 1. ED-EQPT Command Parameters, ED-EQPTtidaideqptsctageqptnblkpst, IP c

Models: 4200

1 382
Download 382 pages 39.36 Kb
Page 148
Image 148
ED-EQPT

7. Equipment Commands

ED-EQPT

The ED-EQPT command edits configuration data associated with equipment supported by the system.

Table 7-1. ED-EQPT Command Parameters

ED-EQPT:[tid]:aid_eqpts:[ctag]::[eqpt_nblk]:[pst];

RESTRICTIONS: All parameters in this command are position-defined.

[tid]

Identification of the target NE. The default value is null. The NE SID

 

code is the only other valid value.

 

 

aid_eqpts

Access identifier of an equipment unit. The value can be preceded with

 

AID=, but this is not required. Enter in one of the following formats,

 

replacing lower-case parameters with the values given:

 

LT-rack-shelf-slot

 

LTA (Line Termination Unit A)-rack-shelf-slot

 

– rack: Rack number (1)

 

– shelf: Shelf number (1)

 

– slot: LT slot number (1)

 

Grouping and ranging are allowed.

 

 

[ctag]

Correlation tag (16 characters) that links an input command with

 

associated output responses. The default is 0.

 

 

[eqpt_nblk]

Named parameter block for equipment. Consists of the following

 

parameter name followed by an equal sign and a valid value:

 

– SWVER: Version of software that is configured (132 characters).

 

Input is case-sensitive. If not specified, the value of this

 

parameter remains unchanged. The system resets whenever the

 

software version is changed.

 

 

[pst]

Desired Primary State (LT or ACU only). Valid value is IS (In-Service). If

 

not specified, the value of this parameter remains unchanged.

Response Format

If, in less than 2 seconds, a normal or error response cannot be sent, the following acknowledgment response is sent:

IP c

After the above response, a new command input may be generated.

Normal Response:

sid yy-mm-dd hh:mm:ss

Mc COMPLD

/* ED-EQPT:[tid]:aid_eqpts:[ctag]::[eqpt_nblk]:[pst] */

;

7-2

August 2002

4200-A2-GB20-00

Page 148
Image 148
Paradyne 4200 manual Ed-Eqpt, 1. ED-EQPT Command Parameters, ED-EQPTtidaideqptsctageqptnblkpst, Response Format, IP c