Paradyne 4200 3-33, RTRV-ADSLtidaidadslctagpstf */ aidERRCDE=errcde error description, Parameter

Models: 4200

1 382
Download 382 pages 39.36 Kb
Page 69
Image 69
/* RTRV-ADSL:[tid]:aid_adsl:[ctag]::::[pstf] */ aid:ERRCDE=errcde

3. ADSL Facility Commands

Error Response:

sid yy-mm-dd hh:mm:ss M c DENY

/* RTRV-ADSL:[tid]:aid_adsl:[ctag]::::[pstf] */ aid:ERRCDE=errcde

/* error description */

;

Table 3-26. RTRV-ADSL Response Parameters (1 of 2)

Parameter

Explanation

 

 

tid

Target NE identification

 

 

yy-mm-dd

Year, month, and day

 

 

hh:mm:ss

Hour, minute, and second

 

 

M

Message generated in response to an input command

 

 

c

If provided, ctag; otherwise 0

 

 

COMPLD

Completed

 

 

DENY

Input command is denied

 

 

/* */

Enclosed are human readable comments – unspecified format

 

 

aid_adsl

As described for command parameters (see Table 3-25,RTRV-ADSL

 

Command Parameters), except that ALL is not used

 

 

adsl_nblk

Named parameter block for ADSL line. The block consists of one or

 

more of the following parameters, in any order separated by commas,

 

each followed by an equal sign and a valid value.

 

ADSLPROF: ADSL Line Profile (130)

 

ADSLPROFNM: ADSL Line Profile name

 

ATMACCPROFF: ATM access profile index for the ADSL fast channel

 

(numeric index of 2)

 

PORTID: Port identifier (132 characters). Indicates the user to whom

 

the port is assigned.

 

QOSCLASSF: Quality of Service for the ADSL Fast channel. Valid value

 

is UBR (Unspecified bit rate).

 

EWL: Equivalent Working Length. Specifies the length of the DSL line.

 

This value is used to limit transmit rates and maximum power settings

 

according to local spectrum management guidelines. EWL is usually

 

specified by the carrier. The values supported are:

 

– 8.5 to 14.5 kft in .5 kft increments

 

– >14.5 kft

 

POTSLVL: POTS Level. Specifies the voltage used to detect the

 

presence of Plain Old Telephone Service (POTS) on the DSL line. The

 

values supported are:

 

– 0 to 74 volts, in 1-volt increments (setting to 74 volts disables

 

POTS detection)

 

– Disable (disables POTS detection)

 

 

4200-A2-GB20-00

August 2002

3-33

Page 69
Image 69
Paradyne 4200 manual 3-33, RTRV-ADSLtidaidadslctagpstf */ aidERRCDE=errcde error description, Error Response, Parameter