Paradyne 4200 15-3, OPR-LPBK-T1tidaidds1ctag,,,lpbktype */ aidERRCDE=errcde, RLS-LPBK-T1 on page

Models: 4200

1 382
Download 382 pages 39.36 Kb
Page 301
Image 301
/* OPR-LPBK-T1:[tid]:aid_ds1:[ctag]::,,,[lpbktype] */ aid:ERRCDE=errcde

15. Test Commands

Error Response:

sid yy-mm-dd hh:mm:ss M c DENY

/* OPR-LPBK-T1:[tid]:aid_ds1:[ctag]::,,,[lpbktype] */ aid:ERRCDE=errcde

/* error description */

;

Table 15-2. OPR-LPBK-T1 Response Parameters

Parameter

Explanation

 

 

sid

Source NE identification

 

 

yy-mm-dd

Year, month, and day

 

 

hh:mm:ss

Hour, minute, and second

 

 

M

Message generated in response to an input command

 

 

c

If provided, ctag; otherwise 0

 

 

COMPLD

Completed

 

 

DENY

Input command is denied

 

 

/* */

Enclosed are human readable comments – unspecified format

 

 

errcde

Error code (see Appendix A, Error Codes)

 

 

Example

Place NTT1 circuit 1 in payload loopback mode.

OPR-LPBK-T1:TAMPA:NTT1-1:40::,,,PAYLOAD;

TAMPA 01-11-24 12:30:43

M40 COMPLD

/* OPR-LPBK-T1:TAMPA:NTT1-1:40::,,,PAYLOAD */

;

Related Command

RLS-LPBK-T1on page 15-7

4200-A2-GB20-00

August 2002

15-3

Page 301
Image 301
Paradyne 4200 15-3, OPR-LPBK-T1tidaidds1ctag,,,lpbktype */ aidERRCDE=errcde, 2. OPR-LPBK-T1 Response Parameters, Example