Connect Tech CTIM-00044 user manual Hardware Information, Hardware Resources, Chip Selects

Page 48

Connect Tech Blue Heat/Net Sync User Manual

Software Development

Hardware Information

The information provided in this section will offer data pertaining to the hardware components present within the Blue Heat/Net Sync unit. Hardware information documentation will encompass hardware resources, base address map, memory map and table, as well as, PLD registers.

Hardware Resources

The hardware resources available for use in software development for the Blue Heat/Net Sync, include; chip selects, interrupts, ColdFire MCF5272 GPIO.

Chip Selects

 

 

 

 

Chip

Usage

Data Bus

Address Range

Cycle Termination

Select *

 

Width

 

 

/CS0

This chip select is used

16 bits

0xFE00 0000 –

- Internal WS logic.

 

to boot the CPU from

 

0xFE80 0000

- 5 wait states.

 

the Flash. The Flash is

 

 

 

 

8M Byte in size.

 

8 Mbytes

 

 

 

 

 

 

/CS1

Used to select the

16 bits

0x4000 0000 –

External /TA signal

 

IUSCs and the internal

 

0x4000 2000

 

 

PLD registers.

 

 

 

 

 

 

8 kbytes

 

/CS2

Dual Ported RAM. 32k

16 bits

0x8000 0000 –

External /TA signal

 

Bytes total size

 

0x8000 8000

 

 

 

 

32 kbytes

 

/CS2

Undefined. For future

Undefined, but

Undefined.

Undefined.

 

expansion or debugging

could be 8 or

 

 

 

purposes. Available on

16 bits

 

 

 

debug header P11 on

 

 

 

 

page 8 of Schematic

 

 

 

/CS7

Used for SDRAM. The

32 bits

0x0000 0000-

Internal WS logic and

 

SDRAM is 16M Bytes

 

0x0100 0000

SDRAM controller.

 

in size.

 

 

 

 

 

 

16 Mbytes

 

 

 

Table 5: Chip Selects

 

48

Revision 0.03

Image 48
Contents Blue Heat/Net Sync Limited Lifetime Warranty Telephone/Facsimile Email/InternetMail/Courier Preliminary Testing is still pending Class a Computing DeviceTable of Contents Installing the Blue Heat/Net Sync Configuration Manager List of Figures List of Tables Introduction Blue Heat/Net Sync Installation Overview Understanding Virtual COM PortsConnecting the Blue Heat/Net Sync to Your Network Ethernet LEDsConnecting Serial Devices Serial Port LEDsConnections Blue Heat/Net Synchronous Clocking RS-422/V.11 ConnectionsLoopback Connectors Recommended Pinouts for V.28 RS-232 Loopback ConnectorConnecting Power DC Power ConnectorPhoenix Locking Screw Terminal Connector 5VDC Activating the Special Operations Mode and Default Settings Selecting a Special OperationPower On Diagnostics LED Error CodesCRC Connect Tech Setting a Static or Dynamic IP Address SCM Serial Configuration ManagerSCM Cabling requirements Set the IP Address Using the Web Configuration Manager Set the IP Address Using the Serial Configuration ManagerConfiguration Manager BootloaderSerial Configuration Manager SCM Application  Operating System SoftwareCDS Configuration Data Space Access to CDS ParametersConfiguration Data Space CDS DescriptionSCM Serial Configuration Manager Getting Access to the SCMSCM Command Reference Brief Command ListCommand Details Boot Syntax boot mode= file= delay=Yes Myip= mip= Save File= WCM Web Configuration Manager Signing In to the Web Configuration ManagerBlue Heat/Net Sync Settings Configure Advanced Serial Settings Configure Blue Heat/Net Sync SettingsPage Configure Firmware Restore DefaultsRestore Default Settings Saving To FlashMonitoring Your Blue Heat/Net Monitor Serial Port TrafficMonitor Network Traffic Monitor TCP/IP StatisticsMy Blue Heat/Net Sync My Blue Heat/Net Sync Hardware Details Installing the Blue Heat/Net Sync Configuration Manager Blue Heat/Net Sync Driver/Software Installation CDBlue Heat/Net Sync Software Installation Screen Page Page Running the Configuration Manager Device InstallationConfigure Default Blue Heat/Net Sync Add New Blue Heat/Net SyncAuto Discover Blue Heat/Net Sync Auto Discover Blue Heat/Net Sync ScreenUpgrade using WCM Web Configuration Manager Upgrade using SCM Serial Configuration ManagerHardware Information Hardware ResourcesChip Selects Chip SelectsBase Address Map InterruptsGpio Bits Direction Usage Address Range hexIusc Access Memory Map of Iusc and PLD FunctionsColdFire 5272 Bus A11 A10PLD Resource Access Address Area item Register Offset Accessed HexPLD Memory Map Table FunctionBit Serial Data transfers only IUSC-1 Offset Reg Name Valid Bit Descriptions Reset Values Hex PLD RegistersFSM CTSM1 CTSM0 PLD ID System Block Diagrams Revision Port Settings, Clock Setup and General Settings BHNPortSettingsSerial Mode smode Async MonoSync BiSync Trans-BiSync Iusc Clocking Logic Blue Heat/Net Sync Specifications Protocol Descriptions TelnetMode Equivalent Standard Electrical Typical Voltage PinoutsDB-25 Female Pinouts DB-25 Female PinoutsDB-9 Female Pinouts DB-9 Female PinoutsRack Mount Option Default Settings Network SettingsBoot Settings SCM Operation SettingsCommon Configuration Setups Static IP SetupUsing SCM Using WCMHow the Blue Heat/Net Sync Boots Up Dhcp SetupBootup Sequence Bootup SequenceFlowchart of Special Operations Mode using the reset button Asynchronous Communications TutorialSerial Line Interface Tutorial RS-232 Line InterfaceDifferential Line Interfaces RS485/RS422/V.11 DetailsBasic 4-Wire, Full Duplex Communications Multi-drop 4-Wire, Full Duplex Communications Basic Wire, Half Duplex Multi-drop ConnectionBus Contention on Differential Multi-drop Networks Termination Resistors in Differential Networks Termination Resistors in Differential Networks