Page 33

AsantéHub 2072 Network Management Module Installation Guide

System Administration Information

Use to enter and transmit text strings defining the hub name, contact, and location.

Out-of-Band Parameters

Use to enter and transmit the Out-of-Band baud rate, dial string to be used when the AMS dials out on a modem, and the Out-of-Band password. Baud rate changes also will be effective on the terminal.

The Out-of-Band password applies when you are establishing an Out-of-Band connection with the hub using AsantéView Out-of-Band and the RS232 port. See the appropriate Asanté- View User’s Guide for more information.There is no password checking when you use the direct link to the hub using the AMS Link ports.

TCP/IP Parameters

Use to define the hub IP address, IP subnet mask, and default router IP address.The new parameters take effect after you restart the hub.

Bootstrap Parameters

Use to define where the hub should boot from (local from EEPROM or from a remote server), what SNMP protocols should be used during the remote boot process, and the IP address of the remote server.

Asanté recommends that you use the default setting of local.

The Boot File Name referred to in the menu is the configura- tion file residing in the AsantéView AMS Images folder in the Macintosh version, and the same directory as the AMS execut- able (In-Band or Out-of-Band) in the Windows version (C:\AVIEW is the default).The default name is 2072h.cfg for the AsantéHub 2072 See the appropriate AsantéView User’s Guide for more information.

SNMP Parameters

Use to define a variety of SNMP parameters:

Read Community string

Write Community string

Authentication trap

Trap receiver table parameters

Page 32

Image 33
Contents AsantéHub 2072 Network Management Module Installation Guide AsantéHub Network Management Module Installation Guide Asking for Assistance AsantéHub 2072 Network Management Module Installation GuideTell Us What You Think Tell Us What You ThinkAH2072NMM Introducing Network Management ModuleIntroducing the Network Management Module Grounding Requirements Checking Package Contents Segment Control InstallationDIP Switch Function of NMM Front Panel Components Front PanelAsanteview OUT-OF Front Panel Cable Connections to Other Devices AMS Link Connecting Hubs in an Out-of-Band Daisy-ChainHub Cable Connections to Other DevicesSummary of DIP Switch Settings DIP switch settings for Out-of-Band using AMS Link Configuration Connecting a Modem to the HubRS232/AMS Link Configuration DIP Switch Setting Using the Local Management PortConnect a straight-through RS232 cable to the RS232 AsantéTerm Icon Using AsantéTermAsanté Remote Management System Main Menu using AsantéTerm Using Telnet Icon for NCSA/BYU Telnet 2.5 Macintosh Upgrading the Hub Image CodeClick the OK button. shows the Asanté General Guidelines Using the Asanté Remote Management SystemAsanté Remote Management System Menu Tutorial Using the Asanté Remote Management SystemExample General Configuration Screen Type the password Asante the password is case-sensi Type a from the Configuration menu.This takes you to Type Office Hub 2072 or a different name if you wish Press q to return to the Configuration menu Accessing the Configuration Menu Configuration MenuConfiguration Menu System Administration Information Group Parameters Console Password Reset System Type c for Console Password Type the new password a second time and press Segment Control An Example for Segmenting the NetworkSelecting a Slot for Segment Change Segment ControlSegment LED States Isolating Modules from the NetworkTechnical Specifications RS232 ConnectionsTechnical Specifications Index IndexEeprom MIB Snmp