Segment Control

Setting Segment Control This section explains how to first select a module for a segment Manually change and then perform the actual segment change. Figure 27

summarizes the steps.

AMS LINK

OUT OF

BAND

SETUP

Select Slot buttonChange Segment button

ASANTEVIEW

SEGMENT CONTROL

 

OUT-OF-BAND

PRESS BOTH BUTTONS TO SET

SEG 2

TERMINATION

 

 

 

 

RS232/AMS LINK

SELECT

CHANGE

SEG 1

 

CONFIGURATION

SLOT

SEGMENT

 

Step 1. Press Select Slot button until specified slot is chosen.

Step 3. Press both the Select Slot and Change Segment buttons at the same time to set the new segment selection.

Step 2. Press Change Segment

button until specified segment is chosen.

Figure 27 Selecting a Slot for Segment Change

ΔTo ensure that you maintain network manage- ment capabilities, you must make sure that your AsantéView Management Station (AMS), which is running AsantéView management software, is on the same segment as the NMM. (Segment 1 is the default setting.)

To manually select a module for segment change, complete the following steps.

1

Press the Select Slot button.

 

If the NMM is set to Segment 1, pressing the Select

 

Slot Button causes the Segment 1 LED to flash. If the

 

NMM is set to Segment 2, pressing the Select Slot But-

 

ton causes the Segment 2 LED to flash. If the NMM is

 

isolated (set to neither segment), pressing the Select

 

Slot Button causes both segment LEDs of the NMM

 

module (Seg 1 and Seg 2) to flash.

2

Continue pressing the Select Slot button until you

 

have chosen your specified slot.The Segment LED for

the specified slot begins flashing.

Page 39

Image 40
Contents AsantéHub 2072 Network Management Module Installation Guide AsantéHub Network Management Module Installation Guide AsantéHub 2072 Network Management Module Installation Guide Asking for AssistanceTell Us What You Think Tell Us What You ThinkIntroducing Network Management Module AH2072NMMIntroducing the Network Management Module Grounding Requirements Checking Package Contents Installation Segment ControlDIP Switch Front Panel Function of NMM Front Panel ComponentsAsanteview OUT-OF Front Panel AMS Link Connecting Hubs in an Out-of-Band Daisy-Chain Cable Connections to Other DevicesCable Connections to Other Devices HubSummary of DIP Switch Settings DIP switch settings for Out-of-Band using AMS Link Connecting a Modem to the Hub ConfigurationUsing the Local Management Port RS232/AMS Link Configuration DIP Switch SettingConnect a straight-through RS232 cable to the RS232 Using AsantéTerm AsantéTerm IconAsanté Remote Management System Main Menu using AsantéTerm Using Telnet Upgrading the Hub Image Code Icon for NCSA/BYU Telnet 2.5 MacintoshClick the OK button. shows the Asanté Using the Asanté Remote Management System General GuidelinesUsing the Asanté Remote Management System Asanté Remote Management System Menu TutorialExample General Configuration Screen Type the password Asante the password is case-sensi Type a from the Configuration menu.This takes you to Type Office Hub 2072 or a different name if you wish Press q to return to the Configuration menu Configuration Menu Accessing the Configuration MenuConfiguration Menu System Administration Information Group Parameters Console Password Reset System Type c for Console Password Type the new password a second time and press An Example for Segmenting the Network Segment ControlSegment Control Selecting a Slot for Segment ChangeIsolating Modules from the Network Segment LED StatesRS232 Connections Technical SpecificationsTechnical Specifications Index IndexEeprom MIB Snmp