AsantéHub 2072 Network Management Module Installation Guide
Pressing a sets the node summary aging time, which is the amount of time the hub stores node summary data. Each time a new device uses a port, or the frame type changes, the hub stores an entry in the Node Summary log. If the hub does not receive data again from that node within the specified aging time, the node data is purged from the log.
▲If the aging time is set to a short time span, prob- lem nodes may time out and be dropped from the Node Summary table.
Console Password
Use to set the password for the terminal interface connection. The password is
Telnet Idle Timeout
Use to set the length of idle time, in whole minutes, before Tel- net closes the current connection.The default is 20 minutes. To keep Telnet from timing out at all, set the idle time to zero minutes.
Toggle Segment Switch Lock/Unlock
Use to enable/disable manual segment control.When manual segment control is disabled, pressing the two segment control buttons on the standard NMM faceplate does nothing.
Reset EEPROM on NMM Module to Default
Use to set
The hub IP address, subnet mask, and default router IP address are set to all zeros. Console Password is set back to its default, which is Asante. Telnet Idle Timeout is also set back to its default, which is 20 minutes.These changes occur on hub restart.
Reset EEPROM on All Repeater Module(s) to Default
Use to set port
Auto Polarity
Enabled.These changes occur immediately.
Page 34