Motorola SM56 manual Modem response line Description

Page 39

Table 14– callCleared codes from 3.6.4/V.58-1994

Value

Description

Notes

 

 

 

51

DteHangupCommand

If ATH was used to terminate the previous

 

 

call.

52

DteResetCommand

If ATZ was used to terminate the previous

 

 

call.

 

 

 

5A

FrameReject

Error Control

 

 

 

5B

NoErrorControlEstab-

Error control was required

 

lished

 

5C

ProtocolViolation

 

 

 

 

5D

n400exceeded

 

 

 

 

5E

NegotiationFailed

 

 

 

 

5F

DisconnectFrameRe-

 

 

ceived

 

 

 

 

60

SabmeFrameReceived

 

 

 

 

64

LossOfSynchroniza-

Data Compression

 

tion

 

Example Modem Response and Usage

Table 15 - Completed Data Call, with some errors and rate retrain during the call

Modem response line

Description

 

 

DIAG <2A4D3263 0=10

This is version 1.0

 

 

DIAG <2A4D3263 1=06 2=0 3=0>

Data Answer signal detected; Data only;

 

Character async

DIAG <2A4D3263 5=“C14513902A”

V.8 Call Menu indicates:

6=“A145”

 

 

V.8 Joint Menu selects:

 

 

DIAG <2A4D3263 10=1F 11=0C

Receive level = -31dbm; transmit level =

12=52>

-12dbm; noise level = -82dbm

DIAG <2A4D3263 14=03 15=05

Far end echo delay in milliseconds; Far

16=10>

end echo loss in dB; Near end echo loss

 

= 16 dB

DIAG <2A4D3263 20=C 22=780

Transmitter: V.34 training completed;

24=0C80 26=79E0 >

V.34 carrier frequency = 1920; V.34

 

symbol rate = 3200; initial transmit rate

 

is 31200 bit/s

 

 

DIAG <2A4D3263 21=D 25=1F40

Receiver: V.90 training completed; V.90

27=DAC0 >

symbol rate = 8000; initial receive rate is

 

56000 bit/s

 

 

37

Image 39
Contents AT Command Reference Manual UbiSurf SM56 Introduction Page AT and AT& Commands Pulse Dial Speaker VolumeReturn to On-Line Mode Speaker ControlSelect Call-Progress Result Codes to Return Reset Modem Parameters to Default ConfigurationTone Dial Result-Code FormatCTS Control Initialize modem to default factory configurationDial TX Level Pulse CycleMaximum Modulation Rate AT% Percent and AT\ Backslash CommandsData Compression DC Mode Disconnect Buffer DelayMinimum Modulation Rate AT% Percent and AT\ Backslash Commands Disconnect on DTE Inactivity Error-Correction EC ModeBreak Handling Method DTE Flow ControlLow-Speed Operation Protocol AT* Asterisk CommandsModulation Mode Dial WaitMM14 K56flex Auto-modulation MM15 Only MM16 MM17 MM18 AT+ Plus Commands +A8E Configuration+A8T 8bis Signal and Message Control Data Compression Control +DRData Compression DC Reporting +DS+EB +ER+ES +ESA Synchronous Access Mode Configuration+ETBM +FCLASS+FLO +FRH +FMI?+FMM? +FMR?AT+ Plus Commands +IFC +GMI+GMM +GMR+MR +PCW +PMH+PMHT +VCID +PMHR+PMF +PQC+VIP +VEM+VGR +VGT+VRID +VRX+VSD +VSM +VTD+VTS +VTX Enter Voice-Transmission ModeATS S-Register Commands S92 Modem-on-Hold Messaging Monitoring S18 Test TimerS11 Tone Length S12 Escape Code Guard TimeCommand Syntax Command ResponseAT#UD Last Call Status Report Format Ffffffff Call Setup Result Codes DTE-DCE modes Multimedia modesGstnModulationSchemeActive from 3.7.2/V.58 ErrorControl Active from 3.5.2/V.58CallCleared codes from 3.6.4/V.58-1994 CompressionActive from 3.2.2/V.58CallCleared codes from 3.6.4/V.58-1994 Modem response line Description Event Reporting Word Busy