3Com 1.024.1644-00 manual S27

Page 75

 

 

 

Technical Reference

Register

Default

Function

 

 

S27 (Continued)

Bit

Value

Result

 

 

2

4

Disables V.32 modulation.

 

 

3

8

Disables 2100 Hz answer tone to

 

 

 

 

allow two V.42 modems to connect

 

 

 

 

faster.

 

 

4

16

Enables V.23 fallback mode.

 

 

5

32

Disables V.32bis mode.

 

 

6

64

Disable V.42 selective reject.

 

 

7

128

Software compatibility mode. This

 

 

 

 

setting disables the codes and

 

 

 

 

displays the 9600 code instead. The

 

 

 

 

actual rate of the call can be viewed on

 

 

 

 

the ATI6 screen. Used for unusual

 

 

 

 

software incompatibilities. Some

 

 

 

 

software may not accept 7200,

 

 

 

 

12,000, and 14,400 bps or greater

 

 

 

 

result codes.

S28

0

Eliminates the V.32 answer tones for a faster connection.

 

8

Default item, all times are in tenths of seconds.

 

255

Disables all connections except V.32 at 9600 bps.

S29

20

Sets the duration, in tenths of a second, of the V.21

 

 

answer mode fallback timer.

S30

0

Reserved

 

 

S31

128

Reserved

 

 

69

Image 75
Contents 56K Voice Faxmodem Internal Page Table of Contents Page Table of Contents Page Welcome to 56K*Information Access Product Features Back Channel Link Rates Upload Speeds Flash ROM Upgradable Control Panel Determining Available ResourcesDetermining Your Version of Windows Click PropertiesWindows 95 version How to Prepare for Plug and Play Installation Plug and Play InstallationSerial Number How to Insert the Modem into the ComputerPage Page Page Page Moving Through the New Hardware Found Screens Installing Modem Drivers With Windows Versions 950 and 950aPage COM Port Click More Info… Using the Update Device Driver Wizard Screens Installing Modem Drivers With Windows Version 950bPage COM Port Click More Info… Word about COM Ports and IRQs How to Change the Modem’s Settings Page How to Insert the Modem into the Computer Page Page Page Page Restart Now Windows Software InstallationType of Modem Initialisation StringFlow Control Read This First Possible SolutionTroubleshooting Possible Solution Possible Solution Possible Solution Troubleshooting Possible Solution Support Resources Support Resources Are You Still Having Problems?Application Analogue signalsAnswer mode Analogue loopbackGlossary Bit rate Glossary Auto dialBaud rate Binary digit bitClass 1 Data modeGlossary Character Characters per second CPSGlossary DefaultDetect phase Digital signalsFlow control Glossary Error controlFax mode FacsimileOFF/ON hook Local echoModem Nonvolatile memory NvramProtocol Originate modeGlossary Online fallback/fall forward ParityTerminal Terminal modeSerial transmission Start/stop bitsSee online fall back/fall forward 22 bis27ter 32 bisYmodem G 42 bisXmodem YmodemTechnical Reference En Sets local echo Technical ReferenceITU-T answer sequence Dials the specified phone number, includes the followingMn Operates speaker Ln Controls speaker volume internals onlyTechnical Reference Hn Controls ON/OFF hook Displays the following informationVerbal codes Numeric codes11/RINGING Technical Reference Sets result code displayed, default isTechnical Reference Cn Controls Carrier Detect CD signal Resets modemDisplays a list of ampersand & commands An Enables/disables additional result code subsets see XnHn Sets Transmit Data TD flow control see also &Rn Fn Loads a read-only non-programmable factory configurationKn Enables/disables data compression Sets Guard Tone300 bps Sets pulse rotary dial make/break ratio No restrictions on the minimum speed for Yn Sets break handling Wn Writes current configuration to Nvram templates64 56K Voice Faxmodem Internal User’s Guide Registers Register Default FunctionBit Value Result Default FunctionS13 Technical Reference Register Default FunctionTimer S27 See the instructions for S13 S34 Bit +FCLASS=n Sets the mode of operation Fax Commands+FTH=n +FRH=nDisplayed As a number Words Description CE Compliance RegulatoryLimited Warranty