Superior SS2000MD4 installation instructions Power Input

Page 12

Danaher Motion Superior Electric

3.3.2 Power Input

The DC input power is connected to terminals 5 and 6 of the terminal strip (J1). Terminal 5 [Vm(+)] is the power supply plus (+) connection and pin 6 [Vom(-)] is the power supply minus (-) connection.

An unregulated supply similar to that shown in Figure 3.4 is preferable. If a regulated supply is used, it must be capable of operating with the added filter capacitor. A switching regulated supply may not be suitable for use with this drive. It is important that the capacitor (C1) be connected within three feet (0.9 meter) of the input terminals. The capacitor must be of the correct value and have the proper current and voltage parameters (see list of components).

It is recommended that the power supply leads be twisted together (6 twists per foot).

If the power supply is grounded, it must only be grounded on the negative side or the short circuit protection will not operate properly.

T1

F1

24 VAC

BR1

R1

J2 Drive

 

 

 

AC +

 

5

Vm (+)

 

 

 

C1

6

 

AC -

 

Vm (-)

 

 

 

 

 

The cable between the filter capacitor (C1) and the drive should be twisted (six twists per foot). Maximum wire length is three feet.

Use #16 AWG or larger wire.

Figure 3.4 Typical Power Supply For A Single Drive Application

 

Components

F1

1.5 ampere time delay, 250 volt

R1

5 ohm surge limiter, Phillips 2322-654-6158 or equivalent

T1

130 VA, 24 VAC output

BR1

General Instrument GBPC3502 or equivalent

C1

4700 µf, 5.5 ampere 20 kHz, 63 V rated, United Chemcon

 

53D472F063HS6 or equivalent

SS2000MD4

12

400030-043 Rev G

Image 12
Contents Rev G Copyright Information Safety Danaher Motion Superior Electric Table of Contents Using this Manual Product FeaturesIntroduction Express Start UP Failure to do this Results in a Shock HazardInstallation Guidelines MountingTerminal Locations and Assignments Terminal LocationsMotor Connections Motor Wiring Configurations Power Input Specifications MechanicalElectrical EnvironmentalMotors for USE with the SS2000MD4 TRANSLATOR/DRIVE Current Settings Step ResolutionSignal Descriptions Signal SpecificationsIndicator Lights Timing RequirementsTorque Versus Speed Characteristics Motor PerformanceTypical Torque Versus Speed Curves Danaher Motion Superior Electric SS2000MD4 Danaher Motion Superior Electric SS2000MD4 Danaher Motion Superior Electric SS2000MD4 Danaher Motion Superior Electric SS2000MD4 Danaher Motion Superior Electric SS2000MD4 Danaher Motion Superior Electric SS2000MD4 Danaher Motion Superior Electric SS2000MD4 Danaher Motion Superior Electric SS2000MD4 Danaher Motion Superior Electric SS2000MD4 Danaher Motion Superior Electric SS2000MD4 Danaher Motion Superior Electric SS2000MD4 Danaher Motion Superior Electric SS2000MD4 Danaher Motion Superior Electric SS2000MD4 Danaher Motion Superior Electric SS2000MD4 Danaher Motion Superior Electric SS2000MD4 System Checking GeneralAppendix a Troubleshooting Electrical Interference ProblemsCustomer Support