SECTION 2: EXPRESS START UP

The following instructions define the minimum steps necessary to make your Drive operational.

Always disconnect the AC power to the unit and be certain the "PWR

ON" LED is OFF before connecting or disconnecting the motor leads.

FAILURE TO DO THIS RESULTS IN A SHOCK HAZARD.

Always operate the Motor and the Drive GROUNDED. Be sure to twist together the wires for each motor phase. Six twists per foot is a good guideline.

1.Check to see that the motor used is compatible with the drive. Refer to Section 4.4 for a list of compatible motors.

2.Set the correct current level for the motor being used per the instructions in Section 4.5. Heat sinking may be required to maintain case temperature below +70° C (+158° F).

3.Select the appropriate step resolution and set the front panel switches as described in Sec- tion 4.6.

4.Wire the motor per the "Motor Connections" description in Section 3.2.

5.Connect the power source to the DC input terminal strip. Be sure to follow the instructions for connecting the filter capacitor as described in Section 3.2, under Power Input.

If the motor operates erratically, refer to Section 5, "Torque Versus Speed Characteristics". Clockwise and counter-clockwise directions are properly oriented when viewing the motor from the end opposite the mounting flange.

SS2000MD4

7

400030-043 Rev G

Image 7
Contents Rev G Copyright Information Safety Danaher Motion Superior Electric Table of Contents Product Features Using this ManualIntroduction Failure to do this Results in a Shock Hazard Express Start UPMounting Installation GuidelinesTerminal Locations Terminal Locations and AssignmentsMotor Connections Motor Wiring Configurations Power Input Environmental SpecificationsMechanical ElectricalMotors for USE with the SS2000MD4 TRANSLATOR/DRIVE Step Resolution Current SettingsSignal Specifications Signal DescriptionsTiming Requirements Indicator LightsMotor Performance Torque Versus Speed CharacteristicsTypical Torque Versus Speed Curves Danaher Motion Superior Electric SS2000MD4 Danaher Motion Superior Electric SS2000MD4 Danaher Motion Superior Electric SS2000MD4 Danaher Motion Superior Electric SS2000MD4 Danaher Motion Superior Electric SS2000MD4 Danaher Motion Superior Electric SS2000MD4 Danaher Motion Superior Electric SS2000MD4 Danaher Motion Superior Electric SS2000MD4 Danaher Motion Superior Electric SS2000MD4 Danaher Motion Superior Electric SS2000MD4 Danaher Motion Superior Electric SS2000MD4 Danaher Motion Superior Electric SS2000MD4 Danaher Motion Superior Electric SS2000MD4 Danaher Motion Superior Electric SS2000MD4 Danaher Motion Superior Electric SS2000MD4 General System CheckingElectrical Interference Problems Appendix a TroubleshootingCustomer Support