RAD Data comm operation manual Opening the ASMi-31 Case, To open the ASMi-31 case

Page 23

ASMi-31Installation and Operation Manual

Chapter 2. Installation and Setup

 

 

Warning

Caution

Access to the inside of the equipment is permitted only to the authorized and qualified personnel.

To avoid accidental electric shock, always disconnect the interface cables and the power cord before removing the unit from its casing.

Line voltages are present inside ASMi-31 when it is connected to power and/or the lines. Moreover, under certain fault conditions, dangerous voltages may appear on the lines connected to the unit.

Any adjustment, maintenance and repair of the opened instrument under voltage must be avoided as much as possible and, when inevitable, should be carried out only by a skilled technician who is aware of the hazard involved. Capacitors inside the unit may still be charged even after the unit has been disconnected from its source of power.

ASMi-31 contains components sensitive to electrostatic discharge (ESD). To prevent ESD damage, avoid touching the internal components, and before moving jumpers, touch the ASMi-31 frame.

Opening the ASMi-31 Case

To reach the internal jumpers and switches of ASMi-31, it is necessary to open its case.

To open the ASMi-31 case:

1.Disconnect all the cables connected to ASMi-31.

2.Turn the unit over (bottom facing up).

3.Unscrew the four cover screws.

4.Turn the unit over (bottom facing down).

5.After the four screws released, remove the ASMi-31 top cover by pulling it straight up.

Setting the Internal Jumpers and Switches

The internal jumpers and switches located on the ASMi-31 printed circuit board (PCB) are identified in * Baud rates not applicable.

Figure 2-1. Their numbers under heading "Item" in Table 2-1correspond to the identification numbers shown in Table 2-1.

Installation and Setup

2-3

Order from: Cutter Networks

Ph:727-398-5252/Fax:727-397-9610

www.bestdatasource.com

Image 23
Contents RAD Data Communications Headquarters US East US West ASMi-31Order from Cutter Networks Ph727-398-5252/Fax727-397-9610 Warranty Ports Safety Status Safety WarningsRegulatory Information Supplementary Information SafetyModem as INT or EXT, and the second modem as RCV Adjust the jumpers see , Installation and SetupQuick Start Guide Quick Start Guide Contents Card Cage Version List of Figures List of Tables General Power Supply VersionsChapter Introduction OverviewInterfaces Wire twisted pair unconditioned linesControl Signal Transfers DiagnosticsFunctional Description Physical DescriptionManagement ConfigurationsDiagnostic RemoteEthernet 10BT, Ethernet 10B2 BNC Technical SpecificationsTypes ITU V.24/RS-232, V.35, RS-530 or Codirectional 64 kbpsData to the line Master ClockExternal clock The master clock uses Clock derived from the digital interface toEnvironment PhysicalIntroduction Technical Specifications Ambient Chapter Installation and SetupPower Site Requirements and PrerequisitesInstallation and Setup Package ContentsTo open the ASMi-31 case Setting the Internal Jumpers and SwitchesOpening the ASMi-31 Case Jumper Description Values Default Setting ASMi-31 PCB Layout ASMi-31 Internal Jumpers and SwitchesLLB, JP15 To close the ASMi-31 case Connecting the LineItem Jumper Description Values Default Setting Closing the ASMi-31 CaseDTE Interfaces and Matching Adapter Cables Connecting the DTEDTE Interface Connector Description RAD Cable To connect the lineRefer to DC Power Connection Supplement Connecting the PowerTo connect DC power to ASMi-31 Chapter Operation Controls and IndicatorsDCD LED is equivalent to Indication signal Front Panel Controls and IndicatorsNormal LEDs ASMi-31 Controls and Indicators Normal OperationOperating Instructions Turning ASMi-31Off Operation Operating Instructions Diagnostic Tests Chapter Troubleshooting and DiagnosticsTo perform the Local Analog Loopback test Local AnalogLoopback LLB To activate the Remote Digital Loopback Remote LoopbackTests and Diagnostics Diagnostic Tests ASM-MN-214 Card Cage Chapter Card Cage VersionASM-MN-214 Rear Panel ASMi-31/R Front Panel ASMi-31/R Card VersionASM-MN-214 Front Panel Power SupplyApplying power, first connect the plug of the power cord to Installing ASMi-31/RTo install the ASMi-31/R card in the ASM-MN-214 card cage ASM-MN-214 card cage has no power switch. Operation startsCard Cage Version Installing ASMi-31/R Description Appendix a Ethernet InterfaceGeneral DB-25 IR-ETH Connector OptionsProtocol Ethernet Bridge SpecificationsSignal Pin DB-25 RJ-45 Figure A-5 Ethernet Bridge Layout UTP Option Installation and OperationTable A-2 DIP Switches Settings LAN InstallationSwitch Settings LED IndicatorsAppendix A. Ethernet Interface Installation and Operation General Description Appendix B IR-G.703 Codirectional Interface 64 kbpsIntroduction Terminal Block RJ-45 DB-25 Standalone Rack Version EXT ModeModem a INT/RCV ModeOrder from Cutter Networks Ph727-398-5252/Fax727-397-9610 Appendix C Interface Module X.21 ConnectorsTable C-1 Table C-1shows the X.21 DB-15 pin assignmentAppendix C. X.21 Interface Module Figure C-5 INT/RCV Mode Timing Block Figure C-4 EXT Mode Timing BlockTable D-1 Appendix D DTE Interface ConnectorsTable D-1 DTE Interface Signal Assignments Unassigned pins according to X.21 standard Table D-1 DTE Interface Signal Assignments Connecting RS-530 to RS-422 Appendix E Connecting RS-530 to RS-422Table E-1 Connecting RS-530 to RS-422To install a single unit Appendix F Installation in 19 RackInstallation of the ASMi-31 Unit in 19 Rack General Installation of a Single UnitRack see Figure F-2 Figure F-1 Installation of a Single UnitTo install two units Figure F-2 Installation of Two UnitsFigure F-3 Fastening Two Units Together