LAN Installation | For 10BaseT installation, either a straight cable or a |
| required. Use a |
| implement the crossover function internally. Otherwise, use a straight cable. |
Note
Switch Settings
Hubs usually implement the crossover function internally while NICs and other devices do not.
Set switches according to Table
Table A-2 DIP Switches Settings
Switch | Name | Description | Default |
Number |
|
| Setting |
|
|
|
|
1 | SQ/FD | ON: Ethernet | OFF |
|
| OFF: Ethernet |
|
|
|
|
|
2 | CMP | ON: Strips padding bits inserted in | ON |
|
| OFF: Transmits frames over WAN as is |
|
|
|
|
|
3 | FIL | ON: Passes only frames destined for another LAN | ON |
|
| OFF: Disables LAN filter; passes all frames transparently |
|
|
|
|
|
4 | (nc) |
| OFF |
|
|
|
|
Note
LED Indicators
The SQ/FD switch is not used in the Ethernet bridge with the BNC connector option.
Table
Table A-3 IR-ETH Bridge LED Indicators
LED Name | Description | Location | Color |
|
|
|
|
LINK | ON indicates good link integrity (available only in | Panel | Green |
| the 10BaseT version) |
|
|
|
|
|
|
COLL | ON indicates collision on the attached Ethernet | Panel | Yellow |
| segment |
|
|
|
|
|
|
RX | ON when data is received from the Ethernet | Panel | Yellow |
| attached segment |
|
|
|
|
|
|
TX | ON when data is transmitted from the modem to | Panel | Yellow |
| the Ethernet segment |
|
|
|
|
|
|
ERR D4 | Bridge buffer overrun | On board | Red |
|
|
|
|
Installation and Operation |