Chauvet Laser Pointer user manual Control Panel, DMX Operation

Page 14

4.OPERATION

Control Panel

Access control panel functions using the four panel buttons located directly underneath the LED Display.

 

 

 

 

 

 

 

Button

Function

 

 

 

 

 

 

 

 

 

 

 

 

<MODE>

Used to access the menu or to return to a

 

 

 

 

 

previous menu option

 

 

 

 

 

 

 

 

 

 

 

<UP>

Scrolls through menu options in

 

 

 

 

 

ascending order

 

 

 

 

 

 

 

 

 

 

 

<DOWN>

Scrolls through menu options in

 

 

 

 

 

descending order

 

 

 

 

 

 

 

MOD

U

DOW ENT

 

Used to select and store the current

 

<ENT>

 

E

P

N

menu or option within a menu

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The Control Panel LED Display shows the menu items you select from the menu map. When a menu function is selected, the display will show immediately the first available option for the selected menu function. To select a menu item, press <ENT>.

Use <UP> and <DOWN> to navigate the menu map and menu options. Press <ENT> to access the menu function currently displayed or to enable a menu option. To return to the previous option or menu without changing the value, press <MODE>.

DMX Operation

This is the operating mode which will allow for control with an external DMX controller. You must set the starting address for this mode. If this is your first time using DMX, then it is recommended that you refer to the “DMX Primer” section in the “Appendix” of this manual.

When operating in DMX receiving mode, the display will blink at a constant rate in the absence of DMX signal.

Use the following procedure for setting the product to DMX operation.

1.Press <MODE> repeatedly until a number from 001~512 appears on the LED display.

2.Use <UP> and <DOWN> to select the DMX starting address.

3.Press <ENT>.

Scorpion™ GBC User Manual

14

August 2011

Image 14
Contents Laser Light Avoid Direct EYE Exposure Product at a Glance Contact InformationDocument Information Table of Contents Claims What Is IncludedUnpacking Instructions Text ConventionsSafety Notes Stop and Read ALL the Laser Safety Notes below Non Interlocked Housing WarningLaser Safety Notes Laser Safety Labels Reproduction Laser Exposure Laser Emission DataLaser Compliance Statement Laser light Avoid direct eye contactBack Panel IntroductionProduct Overview Product Dimensions Power Linking SetupAC Power Orientation Fuse ReplacementMounting RiggingProper Usage DMX Operation OperationControl Panel Automatic DMX Channel SummaryStandalone Operation Sound-ActiveMaster/Slave Operation Menu FunctionsDMX Channel Values Manual Mode use channels 2~10 in this modePattern selection only when CH1 is between 000~017Channel 2 Values Pattern Selection Technical Information General TroubleshootingSymptom Solutions Applies to World Wide Returns ProcedureContact Us Setting up a DMX Serial Data Link DMX PrimerOutpu Data CablingInpu Setting the Starting Address Product LinkingTechnical Specifications