Data Cabling

To link products together you must obtain data cables. You can purchase CHAUVET® certified DMX cables directly from a dealer/distributor or construct your own cable. If you choose to create your own cable, use data-grade cables that can carry a high quality signal and are less prone to electromagnetic interference.

DMX Data Cable

Use a Belden© 9841 or equivalent cable which meets the specifications for EIA RS-485 applications. Standard microphone cables cannot transmit DMX data reliably over long distances. The cable must have the following characteristics:

Type:

shielded, 2-conductor twisted pair

Maximum capacitance between conductors:

30 pF/ft

Maximum capacitance between conductor and shield:

55 pF/ft

Maximum resistance:

20 ohms/1000 ft

Nominal impedance:

100 ~ 140 ohms

Cable Connectors

Cabling must have a male XLR connector on one end and a female XLR connector on the other end.

DMX connector configuration

 

 

COMMON

 

 

INPU

1

DMX +

1

OUTPU

3

 

3

 

2

DMX -

2

 

Terminator

1 3 2

To avoid signal transmission problems and interference, it is always advisable to connect a DMX signal terminator.

120 ohm ¼ W resistor between pin 2 (DMX -) and pin 3 (DMX +) on the output of the last product

Do not allow contact between the common and the product’s chassis ground. Grounding the common can cause a ground loop, and your product may perform erratically. Test cables with an ohm meter to verify correct polarity and to make sure the pins are not grounded or shorted to the shield or each other.

Scorpion™ GBC User Manual

22

August 2011

Image 22
Contents Laser Light Avoid Direct EYE Exposure Document Information Contact InformationProduct at a Glance Table of Contents Claims What Is IncludedUnpacking Instructions Text ConventionsSafety Notes Laser Safety Notes Non Interlocked Housing WarningStop and Read ALL the Laser Safety Notes below Laser Safety Labels Reproduction Laser Exposure Laser Emission DataLaser Compliance Statement Laser light Avoid direct eye contactProduct Overview IntroductionBack Panel Product Dimensions AC Power SetupPower Linking Orientation Fuse ReplacementMounting RiggingProper Usage Control Panel OperationDMX Operation Automatic DMX Channel SummaryStandalone Operation Sound-ActiveMaster/Slave Operation Menu FunctionsDMX Channel Values Manual Mode use channels 2~10 in this modePattern selection only when CH1 is between 000~017Channel 2 Values Pattern Selection Symptom Solutions Applies to General TroubleshootingTechnical Information Contact Us Returns ProcedureWorld Wide Setting up a DMX Serial Data Link DMX PrimerInpu Data CablingOutpu Setting the Starting Address Product LinkingTechnical Specifications