Code Table (1-a)
[a]Function | [b]Range/Switch Code | Command |
|
|
| ||
|
|
|
| Control | Enquiry | Standby | Power On |
0x7E | On Screen Logo | 0x00 | OFF | Yes | Yes | Enable | Enable |
|
|
|
|
|
|
|
|
|
| 0x01 | ON (Default) |
|
|
|
|
|
|
|
|
|
|
|
|
|
| 0x02 | Reserved |
|
|
|
|
|
|
|
|
|
|
|
|
0x7F | LED | 0x00 | OFF | Yes | Yes | Disable | Enable |
|
|
|
|
|
|
|
|
|
| 0x01 | ON |
|
|
|
|
0x81 | Power On Delay | Yes | Yes | Enable | Enable |
*1: Auto Signal Detect becomes Disable. When Option Slot is connected, Option command is Enable.
*2: Restricts a part of keys operation following below. [Remote Commander]
Menu, Picture, Sound, ECO (Power Saving), Contrast+/_,Brightness, Chroma, H Shift, V Shift, V size, PAP [Main]
Menu
*3: Digital Signal Status is Enable for Digital Input Signal Detect Function only in Stable.
*4: Digital Signal or VIDEO Signal is Enable. Return Signal Status of Active Window.
*5: Only the panel power supply is turned off at the standby when setting it “ON”.
5. Analog Signal Detect Function
(a) Mode Control
Syntax | Header | Category | Function | Data1 | Data2 | Check Sum | |
Enquiry | 0x83 | 0x00 | Code Table | Code Table | 0xFF | 0xXX |
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
| |
Answer | Header | Answer | Return to Data Size | Return Data1 | Data2 | Check Sum | |
Enquiry | 0x70 | 0x00 | 0x02 | Code Table | 0xFF | 0xXX | Completed |
Code Table (1-a)
[a]Function | [b]Range/Switch Code | Command |
|
|
| |
|
|
| Control | Enquiry | Standby | Power On |
0x78 Analog Signal Detect | 0x00 | VIDEO | No | Yes | Disable | Enable |
|
|
|
|
|
|
|
| 0x01 | PC |
|
|
|
|
|
|
|
|
|
|
|
Code Table (1-d)
Input Select
0x00 | Main |
|
|
0x01 | Sub |
|
|
0xFF | Present input |
|
|
When input is no signal or not supported signal, return value become Video(0x00).