Dell SE500W manual Preparing the Perc RAID Adapter for Clustering, Important System Warning

Page 43

In joined-bus and cluster modes, if a secondary EMM receives a message that the primary EMM has failed, the fault LED indicator on the primary EMM is illuminated and the condition is reported back to the host initiator. The secondary EMM then becomes active and holds the failed primary in a state of reset until it is replaced. If the primary EMM detects that the secondary has failed, the secondary’s fault LED indicator is illuminated and the failed status is reported back to the host initiator.

NOTE: In split-bus mode, each EMM controls half of the enclosure. If one EMM fails in split-bus mode, the second EMM reports the failure but does not assume control of the entire SCSI bus.

The primary EMM is always plugged into the slot on the left (viewed from the back of the system). In a redundant joined-bus configuration, the primary EMM assumes control of all the enclosure functionality. In addition, the primary EMM is the only module that reports the status of the system to the host initiator through SES and SAF-TE protocols. Because the secondary EMM must assume the responsibilities of the primary in the event that the primary fails, both the primary and secondary EMMs are continuously monitoring the status of the

system’s components.

Preparing the PERC RAID Adapter for Clustering

The warning message shown in Figure 3-3 appears on your screen when you attempt to modify the configuration of the shared storage system on your cluster by using the PERC RAID adapter BIOS configuration utility.

Figure 3-3. Important System Warning

!!!STOP!!!

This operation may change the configuration of disks and can cause loss of data! Ensure:

1.Peer server is powered up for its controller NVRAM to be updated. Otherwise, disk configuration should be read from disk and saved to controller's NVRAM.

2.The second server must not be configuring the disks.

3.There is no I/O activity against shared drives.

Press Any Key To Continue

The warning message appears on the screen immediately after activating the PERC RAID adapter BIOS configuration utility by pressing <Ctrl><m> during the system’s Power-On Self-Test (POST).

Preparing Your Systems for Clustering

43

Image 43
Contents Installation and Troubleshooting Guide Abbreviations and Acronyms Contents Updating the Windows Driver for the Perc RAID Adapter Assigning Static IP Addresses to Your ClusterNaming and Formatting Drives on Configuring Microsoft Windows Server Installing and Configuring Microsoft WindowsMicrosoft Cluster Administrator Uninstalling Mscs From Clusters Running Setting Advanced Resource PropertiesConfiguring Active and Passive Cluster Nodes Configurations Using Non-Dell ProductsPowerEdge Cluster SE500W Solution Data Form Changing the Cluster Service Account PasswordMaximum Configuration of the PowerEdge Applications and Hardware Requiring Power Cabling Example With Two PowerBus Configuration Switch Modes Important System Warning Private Network Hardware ComponentsIntroduction IntroductionIntended Audience Obtaining More InformationVirtual Servers and Resource Groups Obtaining Technical Assistance OverviewQuorum Resource Shared Storage Systems PowerEdge Cluster SE500W SolutionOperating Systems Storage System Configuration, at least three virtual disks are recommendedEdition X64 Edition Cluster Components Hardware and Software TechnologiesScsi cables System RequirementsCluster storage Cluster NodesCluster Node Requirements Component Minimum Requirement Other Documents You May Need Cabling Your Cluster Hardware Cabling for the Cluster SE500W SolutionCabling Your Cluster Hardware Redundant power supply Shared storage Shared storage connector BPin connector NodePin connectors Cabling Your Cluster Hardware Adapter Channel 0 Perc RAID adapter channel Pin connectorsNetwork Connections Description Cabling Your Public and Private NetworksPrivate network adapter Cluster node Cabling Your Public NetworkNIC Teaming Cabling Your Private NetworkPrivate Network Hardware Components and Connections Method Cabling the Mouse, Keyboard, and Monitor Power Cabling for the PowerEdge Cluster SE500W SolutionPage Power Cabling Example With One Power Supply in the Systems Power Cabling Example With Two Power Supplies in the Systems Cabling Your Cluster Hardware Before You Begin Preparing Your Systems for ClusteringPreparing Your Systems for Clustering Installation Overview Selecting a Domain Model Configuring the Cluster Nodes as Domain ControllersInstalling and Configuring the Windows Operating System Configuring the Internal Drives in Your Cluster NodesPreparing Your Systems for Clustering Configuring Windows Networking Dell recommends using static IP addresses for your cluster Configuring IP Addresses for the Private NetworkHas been corrected in Windows Server Preparing Your Systems for Clustering Verifying Cluster Network Communications Configuring the Internet Connection FirewallUpdating the Windows Driver for the Perc RAID Adapter Installing the Perc RAID AdaptersClustering PowerVault Storage Systems Installing and Configuring the Shared Storage SystemSplit-Bus Module Module Primary Split-busPage Enclosure Management Module EMM EMM serves two primary functions in your storage systemPreparing the Perc RAID Adapter for Clustering Setting the Scsi Host Adapter IDs Enabling the Cluster Mode Using the Perc RAID AdapterNaming and Formatting Drives on the Shared Storage System Configuring and Managing Virtual DisksAssigning Drive Letters and Mount Points EmailData Verifying Cluster Readiness Installing and Configuring MscsCreating the Quorum Resource Configuring Cluster Networks Running WindowsConfiguring Cluster Networks Running Windows Server Preparing Your Systems for Clustering Adding Cluster Nodes Using the Advanced Configuration Option Verifying Cluster Resource Availability Installing Applications in the Cluster GroupVerifying Cluster Functionality Verifying Mscs OperationObtaining More Information Troubleshooting Failed ResourcesRunning Cluster Administrator on a Remote Console Installing Your Cluster Management SoftwareMicrosoft Cluster Administrator Launching Cluster Administrator on a Cluster NodeLaunching Cluster Administrator on a Remote Console Cluster Networks Using MscsUsing Mscs Cluster ObjectsNode-to-Node Communication Network InterfacesCluster Nodes Preventing Network FailureJoining an Existing Cluster Forming a New ClusterCluster Resources GroupsDependent Resources Setting Resource PropertiesSetting Advanced Resource Properties Configuring Resource DependenciesCluster Resources and Required Dependencies Resource Parameters Resources and Configurable ParametersQuorum Disk Quorum Resource Resource Failure Creating a New Resource Adjusting the Threshold and Period ValuesFile Share Resource Type Deleting a ResourceFailover and Failback Configuring Active and Passive Cluster NodesFailover Using Mscs Failback Using Mscs Certification Requirements Upgrading Your System to a Cluster ConfigurationUpgrading Your Operating System Configurations Using Non-Dell ProductsCompleting the Upgrade Upgrading Your System to a Cluster ConfigurationBefore you perform a rolling upgrade Performing a Rolling UpgradeUpgrading Node Adding a Network Adapter to a Cluster Node Maintaining Your ClusterMaintaining Your Cluster IP address Maintaining Your Cluster Running chkdsk /f on a Quorum Disk Removing Nodes From Clusters Running Windows ServerRecovering From a Corrupt Quorum Disk Replacing a Cluster Node Replacing a Cluster-Enabled Dell Perc RAID AdapterWhere clustername is the name of your cluster Reformatting a Cluster Disk Maintaining Your Cluster Rebuilding Operation in Dell OpenManage Utilities Maintaining Your Cluster Maintaining Your Cluster Troubleshooting TroubleshootingPerc 3/DC Bios Troubleshooting Administrator’s Guide for instructions on Viewer, see the Microsoft Cluster ServiceSupport.microsoft.com Troubleshooting Troubleshooting Abbreviations and Acronyms Abbreviations and AcronymsGUI NLB RAM Abbreviations and Acronyms Cluster Data Form PowerEdge Cluster SE500W Solution Data FormCluster Data Form System Storage Node Server Type Cluster Name Service Tag Number Server NameStorage, internal drives Dell PowerVault Description of Installed ItemsDrive letters, RAID types, applications/data Component StorageW . d e l l . c o m s u p p o r t . d e l l . c o m Index IndexMscs Shared storage system configuring, 39 enclosure management Replacing a cluster-enabledcardVirtual disks, 45 using dynamic disks Index Example of Network Cabling Connection PowerVault 22 xS Back PanelPage Table A-1 General Cluster Troubleshooting
Related manuals