Chapter 6 - Basic Configuration Guide | 31 |
SMDS Configuration
This section covers the settings required for SMDS (Switched Multi- megabit Data Service) operation of the RISC Router 3500R WAN inter- faces. SMDS is a connectionless,
ϖNote: The IP protocol settings and the physical communication settings are the same as they would be for Frame Relay operation. The only parameters which should be set differently for SMDS are the Link Configuration and the SMDS addressing section.
Link Configuration
SMDS is presently supported in the RISC Router 3500R only via synchronous dedicated line operation. It can only be set using text- based configuration.
•Set Dedicated connection
•Set SMDS connection
TB: Use configure and then set the Mode and ConnectMode keywords in the Link Config WAN 0 (and/or other port numbers you wish to configure) section.
SMDS Addressing
SMDS addresses and other parameters can only be set using the command line interface. Many of these parameters will be given to you by your service provider.
TB: Use configure and set the StationAddress, IPMulticast and Poll- ingFrequency keywords in the SMDS WAN 0 (and/or other port
numbers you wish to configure) section.