Axis Communications Installing the Axis 250S, Unix only Type this in your command line

Page 10

10

Installing the AXIS 250S

AXIS 250S User’s Manual

Installing the AXIS 250S

This section is intended for use by the product administrator. Operators and viewers should read Operating the AXIS 250S, on page 14.

Quick installation - Follow the instructions below to quickly install on an Ethernet network.

Easy installation - See Using the AXIS IP Installer, on page 35.

Other Methods - Please refer to Other IP Setup Methods, on page 35.

Connect a microphone to the Mic connector, or an alternative input device to the Line input.

Connect a video source to the BNC or S-Video connec- tor. (Use a BNC-to-RCA con- verter if your source is supplied with a phono-type (RCA) connector.) The 75 Ohm

selector switch should nor- mally be set to ON. If the unit is connected in parallel (e.g. with a monitor) set this switch to OFF.

Note the Serial number on the underside of the unit. You need to know this to set the IP address.

Serial number same as Ethernet address; e.g.

00408c100086 =

00-40-8c-10-00-86

Using an appropriate method for your operating system, assign your product with a unique IP address from a computer on your network, as follows:

Windows only - Start a Command prompt and type these commands:

Syntax:

arp -s <Server IP address> <Ethernet address> <my PC IP address> ping -t <Server IP address>

Example:

arp -s 172.21.1.200 00-40-8c-10-00-86 172.21.1.193 ping -t 172.21.1.200

UNIX only - Type this in your command line:

Syntax:

arp -s <IP address> <Ethernet address> temp ping <IP address>

Example:

arp -s 172.21.1.200 00:40:8c:10:00:86 temp ping 172.21.1.200

You will now see Request timed out...messages repeatedly returned in the window.

Note: In some Unix systems, the arp command can be located in a directory that is not on the command path.

Image 10
Contents Axis 250S MPEG-2 Video Server Axis 250S User’s Manual Table Of Contents Index Features and Benefits IntroductionAxis 250S User’s Manual Applications Axis 250S Front Panel Product DescriptionAxis 250S Rear Panel Hardware Inventory Title/Variant Part Number Title/Variants Part NumbersInstalling the Axis 250S Unix only Type this in your command lineAxis 250S User’s Manual Installing the Axis 250S Client System RequirementsInstalling the Axis MPEG-2 Viewer Client Accessing the Axis 250S from Internet Explorer Configuring the video source and audio equipmentAccessing and logging on to the Axis 250S Operating the Axis 250SAccess from a browser Live ViewDisconnected Video Source Positional Control of the Video SourceSetting up a new event type Configuring Event TypesEvents and Event Types General When Triggered Upload Servers Adding an Upload ServerNotification Servers Http NotificationAudio & Video Settings VideoAudio Port Status & DevicesPort Status Preset position setup DevicesLive View Layout Administration & System Options Accessing The System OptionsSystem Options Overview Administration DescriptionUsers Editing and Deleting Users Firewall SettingsAdding Users Adding Allowed IP AddressesCurrent Server Time Date & TimeNew Server Time Dynamic IP Address Notification Settings TCP/IP Network SettingsAutomatic IP Configuration Parameter DescriptionManual IP Configuration DNSNetwork Traffic Smtp email Network SettingsPorts & Devices IO PortsSupport Logs & Reports MaintenanceCOM-Port Factory Default Settings Using the Axis IP Installer Appendix a Other IP Setup MethodsInstalling the Axis IP Installer Setting the IP Address with the Axis IP Installer Support Appendix B TroubleshootingChecking the Firmware Server ReportPINGing Your IP Address Ping Reply Interpretation and recommendationSymptoms, Possible Causes and Remedial Actions Symptoms Possible causes Remedial actionsRepeatedly attempts to Attempting to install, but Obtaining Updated firmware Updating the firmware Appendix C Updating the FirmwareAppendix D Customizing The Axis 250S Configuration via FTPModifying the File System Custom Web Pages Customizing ProceduresEditing and Storing Your Web pages Http//server ip address/local/filename.html Creating a New Home Appendix E Unit Connections D-Sub ConnectorConnector Pinout Terminal Blocks a & B I/O Terminal BlocksSchematic Diagram Terminal Connectors a & B Axis 250SBrowser Administration Tools Connecting Pan/Tilt DevicesPan Tilt Device Driver Transistor Output Controlling and MonitoringDigital Inputs Axis 250S then displays the status of the inputs, as follows Appendix F Technical Specifications Approvals EMC Video Bit Rate Appendix G BandwidthImage Quality vs Bit Rate Other Considerations Bootp IndexPTZ devices Reports Axis 250S User’s Manual Index