Acnodes RMC 7189 user manual Handling the Motherboard, Precautions

Page 32

RMC 7189

1U Rackmount System

CHAPTER 5

ADVANCED SERVERBOARD SETUP

This chapter covers the steps required to install processors and heatsinks to the RMC7189 serverboard, connect the data and power cables and install add-on cards. All serverboard jumpers and connections are described and a layout and quick reference chart are included in this chapter. Remember to close the chas- sis completely when you have finished working on the serverboard to protect and cool the system sufficiently.

5-1 Handling the Motherboard

Static electrical discharge can damage electronic components. To prevent damage to printed circuit boards, it is important to handle them very carefully (see Chapter 4). Also note that the size and weight of the serverboard can cause it to bend if handled improperly, which may result in damage. To prevent the serverboard from bending, keep one hand under the center of the board to support it when handling. The following measures are generally sufficient to protect your equipment from static discharge.

Precautions

o Use a grounded wrist strap designed to prevent Electrostatic Discharge (ESD).

o Touch a grounded metal object before removing any board from its antistatic bag.

o Handle a board by its edges only; do not touch its components, peripheral chips, memory modules or gold contacts.

o When handling chips or modules, avoid touching their pins.

o Put the motherboard, add-on cards and peripherals back into their antistatic bags when not in use.

o For grounding purposes, make sure your computer chassis provides excellent conductivity between the power supply, the case, the mounting fasteners and the motherboard.

 

© Copyright 2005 Acnodes, Inc.

661 Brea Canyon Rd., Suite 3

All rights reserved. Product description and product specifications

Walnut, CA 91789

are subject to change without notice. For latest product information,

tel: 909.598.7388, fax: 909.598.0218

please visit Acnodes’ web site at www.acnodes.com.

Image 32
Contents RMC Copyright 2005 Acnodes, Inc Preface Manual OrganizationBios Advanced Motherboard SetupAdvanced Chassis Setup Table of Contents Installing the System in to a Rack System InterfaceAdvanced Motherboard Setup Advanced Chassis Setup Introduction OverviewServerboard Features ProcessorMemory Onboard SataServer Chassis Features Cooling System Choosing a Setup Location Preparing for SetupOverview Unpacking the SystemRack Precautions Server PrecautionsRack Mounting Considerations Installing the System into a Rack Identifying the Sections of the Rack RailsInstalling the Rack Rails Inner RailsOuter Rails RMC Installing the Chassis into a Rack Installing the Server into a Telco Rack Checking the Components Checking the Motherboard SetupRemoving the Chassis Cover Figure Checking the Drive Bay Setup Providing PowerChecking the Drives Checking the AirflowControl Panel Buttons Reset ButtonPower Control Panel LEDs Universal Information LEDNIC2 HardDrive Carrier LEDs System Safety Electrical Safety PrecautionsGeneral Safety Precautions ESD Precautions Operating Precautions Precautions Handling the MotherboardUnpacking Processor and Heatsink InstallationInstalling an LGA1366 Processor RMC Installing the Heatsink Removing the Heatsink Connecting Cables Connecting Data CablesConnecting Power Cables Connecting the Control PanelI/O Ports Memory Support Installing Memory ModulesInstalling DIMMs RMC RMC PCI Card Installation Adding PCI CardsServerboard Details RMC Connector Definitions ATX Power Supply ConnectorProcessor Power Connector Power LEDHDD LED Universal Serial Bus Ports Power Fail LEDPower Button Universal Serial Bus Headers Serial PortsFan Headers Chassis IntrusionOverheat LED Power LED/ SpeakerATX PS/2 Keyboard and PS/2 Mouse Ports LAN1/2 Ethernet Ports Power SMB I2C ConnectorUID Buttons Jumper Settings VGA Enable/DisableExplanation of Jumpers Cmos ClearSMB to PCI Express Slots LAN Enable/DisableWatch Dog Enable/Disable ME Recovery BMC/PHY ResetME Mode Select Ipmi Dedicated LAN LEDs Onboard IndicatorsLAN1/2 LEDs Sata Port Drive Connections Sata PortsInstalling Software Driver/Tool Installation Display ScreenRMC RMC Static-Sensitive Devices Tools RequiredControl Panel System CoolingReplacing a System Fan Figure Adding a System FanSystem Fan Failure Drive Bay Installation/Removal Accessing the Drive BaysHard Drive Installation Installing a Hard Drive into a Drive Carrier FigureRemoving a Hard Drive Figure DVD Drive Installation Power Supply Replacing the Power SupplyRMC Introduction Starting Bios Setup UtilityHow To Change the Configuration Data Main Setup Starting the Setup UtilitySystem Time/System Date System MemoryAdvanced Setup Configurations Xboot Features Quick BootQuiet Boot AddOn ROM Display ModeWait For F1 If Error Restore on AC Power LossPS/2 Mouse Support Hit Del Message DisplayClock Spread Spectrum Hardware Prefetcher Available when supported by the CPUXProcessor & Clock Options CPU Ratio State package limit setting Active Processor CoresIntel Eist Technology Intel TurboMode TechnologyXAdvanced Chipset Control Memory Mode Memory FrequencyDemand Scrubbing Patrol ScrubbingInlet Temperature Temperature RiseAir Flow AltitudeActive State Power Management Numa SupportIntel I/OAT Slot SXB2/SXB3 WidthXide / Floppy Configuration XPCI/PnP Configuration XSuper IO Device Configuration Onboard LAN Option ROM SelectLoad Onboard LAN1 Option ROM/Load Onboard LAN2 Option ROM Uart 2 of Hermon asXRemote Access Configuration XHardware Health Configuration CPU Overheat AlarmCPU 1 Temperature/ CPU 2 Temperature/ System Temperature CPU 1 Temperature/CPU 2 TemperatureFan1 ~ Fan 8 Reading Xacpi Configuration Xipmi Configuration XSet LAN Configuration Clear BMC System Event LogXSet PEF Configuration BMC Watch Dog Timer ActionGateway Address Mac AddressXEvent Log Configuration Security Settings Supervisor PasswordUser Password Change Supervisor PasswordBoot Sector Virus Protection Change User PasswordPassword Check XHard Disk Drives Boot SettingsXBoot Device Priority Exit Options XRemovable DrivesXCD/DVD Drives Save Changes and ExitLoad Optimal Defaults Load Fail-Safe DefaultsDiscard Changes and Exit Discard ChangesAppendix a Post Error Beep Codes Appendix B Installing the Windows Installing Windows OS for a RAID SystemInstalling Windows OS for a Non-RAID Systems Processors ChipsetMemory Capacity Sata ControllerWeight Power Supply RMC7189Chassis System Cooling

RMC 7189 specifications

The Acnodes RMC 7189 is a powerful and robust industrial computer designed to meet the demanding needs of various applications, ensuring reliable performance in harsh environments. Its rugged construction and advanced features make it a suitable choice for industries such as manufacturing, transportation, and automation.

One of the standout features of the RMC 7189 is its impressive processing capability. Equipped with an Intel Core i7 or i5 processor, it delivers high-performance computing power that can efficiently handle complex tasks and multiple applications simultaneously. The device is designed to support up to 32GB of DDR4 RAM, providing plenty of memory for even the most resource-intensive applications, ensuring smooth operation under load.

The RMC 7189 is designed with versatility in mind. It offers multiple I/O options, including COM ports, USB ports, and Ethernet interfaces, allowing for seamless connectivity with various peripherals and network devices. This flexibility is crucial for integrating the unit into existing systems, enabling it to serve as a central hub for data collection and analysis.

To enhance its durability, the RMC 7189 features a fanless design that minimizes points of failure and reduces noise, making it suitable for environments where traditional cooling methods may be impractical. The system is also resistant to dust and moisture, adhering to IP65 ratings, which makes it ideal for use in factories or outdoor settings.

In terms of storage, the RMC 7189 supports multiple options, including SSDs and HDDs, ensuring that users can choose the appropriate storage solution for their specific applications. The system also includes advanced technologies, such as RAID configurations, to provide data redundancy and protection against hardware failures.

Furthermore, the RMC 7189 is equipped with a range of expansion slots, including PCIe and Mini PCIe, allowing for integration with additional cards and modules, such as GPU for enhanced graphical processing or additional network interfaces to support various communication protocols.

The system supports a wide range of operating systems, including Windows and Linux, providing flexibility for users to choose their preferred platform. This feature, combined with its robust hardware specifications, makes the RMC 7189 a highly adaptable solution for modern industrial challenges.

In summary, the Acnodes RMC 7189 is a highly versatile and powerful industrial computer equipped with advanced features and technologies designed to perform reliably in challenging environments. With its robust construction, extensive connectivity options, and high processing capability, it stands out as an excellent choice for industries aiming to enhance their operational efficiency and data management capabilities.