Acnodes RMC 7189 Inlet Temperature, Temperature Rise, Air Flow, Altitude, Dimm Pitch, Intel VT-d

Page 76

RMC 7189

1U Rackmount System

Inlet Temperature

This is the temperature detected at the chassis inlet. Each step is in 0.5oC increment. The default is [070]. Press "+" or "-" on your keyboard to change this value.

Temperature Rise

This item allows the user to define the temperature rise parameter of a memory module to be used to improve memory power management. Each setting is in

0.5oC increments. The default setting is [020]. Press "+" or "-" on your keyboard to change this value.

Air Flow

This item allows the user to set the desired speed of air flow to the DIMM mod- ules. Each incre- ment is one mm/sec. The default is [1500]. Press "+" or "-" on your keyboard to change this value.

Altitude

This item allows the user to specify the altitude of the location where the com- puter is used. For Tylersburg-EP platforms, system memory thermal solution is derated up to 900m. To comply with CPU specifications, BIOS will attempt to adjust and correct DIMM velocity based on the altitude where the system is located in order to improve DIMM thermal performance. Altitude is defined as the number of feet above the sea level where the computer is located. The options are Sea Level or Below, 1~300 (above-), 301~600 (above-), 601~900 (above-),

901~1200 (above-), 1201~1500 (above-), 1501~1800 (above-), 1801~2100 (above-), 2101~2400 (above-), 2401~2700 (above-), and 2701~3000 (above-) the sea level.

DIMM Pitch

Use this feature to specify the distance of physical space between each DIMM module. Each step is in 1/1000 of an inch. The default is [400]. Press "+" or "-" on your keyboard to change this value.

Intel VT-d

Select Enabled to enable Intel's Virtualization Technology support for Direct I/O VT-d by reporting the I/O device assignments to VMM through the DMAR ACPI Tables. This feature offers fully-pro- tected I/O resource-sharing across the Intel platforms, providing the user with greater reliability, security and availability in networking and data-sharing. The settings are Enabled and Disabled.

SR-IOV Supported

Select Enabled to enable Single Root I/O Virtualization (SR-IOV) support which works in conjunc- tion with the Intel Virtualization Technology and allow multiple op- erating systems running simulta- neously within a single computer via natively share PCI-Express devices in order to enhance net- work connectivity and performance. The options are Enabled and Disabled.

 

© Copyright 2005 Acnodes, Inc.

661 Brea Canyon Rd., Suite 3

All rights reserved. Product description and product specifications

Walnut, CA 91789

are subject to change without notice. For latest product information,

tel: 909.598.7388, fax: 909.598.0218

please visit Acnodes’ web site at www.acnodes.com.

Image 76
Contents RMC Copyright 2005 Acnodes, Inc Preface Manual OrganizationAdvanced Chassis Setup Advanced Motherboard SetupBios Table of Contents Installing the System in to a Rack System InterfaceAdvanced Motherboard Setup Advanced Chassis Setup Introduction OverviewServerboard Features ProcessorMemory Onboard SataServer Chassis Features Cooling System Choosing a Setup Location Preparing for SetupOverview Unpacking the SystemRack Precautions Server PrecautionsRack Mounting Considerations Installing the System into a Rack Identifying the Sections of the Rack RailsInstalling the Rack Rails Inner RailsOuter Rails RMC Installing the Chassis into a Rack Installing the Server into a Telco Rack Removing the Chassis Cover Figure Checking the Motherboard SetupChecking the Components Checking the Drive Bay Setup Providing PowerChecking the Drives Checking the AirflowPower Reset ButtonControl Panel Buttons Control Panel LEDs Universal Information LEDNIC2 HardDrive Carrier LEDs System Safety Electrical Safety PrecautionsGeneral Safety Precautions ESD Precautions Operating Precautions Precautions Handling the MotherboardInstalling an LGA1366 Processor Processor and Heatsink InstallationUnpacking RMC Installing the Heatsink Removing the Heatsink Connecting Cables Connecting Data CablesConnecting Power Cables Connecting the Control PanelI/O Ports Installing DIMMs Installing Memory ModulesMemory Support RMC RMC PCI Card Installation Adding PCI CardsServerboard Details RMC Connector Definitions ATX Power Supply ConnectorProcessor Power Connector Power LEDHDD LED Power Button Power Fail LEDUniversal Serial Bus Ports Universal Serial Bus Headers Serial PortsFan Headers Chassis IntrusionATX PS/2 Keyboard and PS/2 Mouse Ports Power LED/ SpeakerOverheat LED UID Buttons Power SMB I2C ConnectorLAN1/2 Ethernet Ports Jumper Settings VGA Enable/DisableExplanation of Jumpers Cmos ClearWatch Dog Enable/Disable LAN Enable/DisableSMB to PCI Express Slots ME Mode Select BMC/PHY ResetME Recovery LAN1/2 LEDs Onboard IndicatorsIpmi Dedicated LAN LEDs Sata Port Drive Connections Sata PortsInstalling Software Driver/Tool Installation Display ScreenRMC RMC Static-Sensitive Devices Tools RequiredControl Panel System CoolingSystem Fan Failure Adding a System FanReplacing a System Fan Figure Drive Bay Installation/Removal Accessing the Drive BaysHard Drive Installation Installing a Hard Drive into a Drive Carrier FigureRemoving a Hard Drive Figure DVD Drive Installation Power Supply Replacing the Power SupplyRMC How To Change the Configuration Data Starting Bios Setup UtilityIntroduction Main Setup Starting the Setup UtilitySystem Time/System Date System MemoryAdvanced Setup Configurations Xboot Features Quick BootQuiet Boot AddOn ROM Display ModeWait For F1 If Error Restore on AC Power LossPS/2 Mouse Support Hit Del Message DisplayXProcessor & Clock Options CPU Ratio Hardware Prefetcher Available when supported by the CPUClock Spread Spectrum State package limit setting Active Processor CoresIntel Eist Technology Intel TurboMode TechnologyXAdvanced Chipset Control Memory Mode Memory FrequencyDemand Scrubbing Patrol ScrubbingInlet Temperature Temperature RiseAir Flow AltitudeActive State Power Management Numa SupportIntel I/OAT Slot SXB2/SXB3 WidthXide / Floppy Configuration XPCI/PnP Configuration XSuper IO Device Configuration Onboard LAN Option ROM SelectLoad Onboard LAN1 Option ROM/Load Onboard LAN2 Option ROM Uart 2 of Hermon asXRemote Access Configuration XHardware Health Configuration CPU Overheat AlarmCPU 1 Temperature/ CPU 2 Temperature/ System Temperature CPU 1 Temperature/CPU 2 TemperatureFan1 ~ Fan 8 Reading Xacpi Configuration Xipmi Configuration XSet LAN Configuration Clear BMC System Event LogXSet PEF Configuration BMC Watch Dog Timer ActionGateway Address Mac AddressXEvent Log Configuration Security Settings Supervisor PasswordUser Password Change Supervisor PasswordPassword Check Change User PasswordBoot Sector Virus Protection XBoot Device Priority Boot SettingsXHard Disk Drives Exit Options XRemovable DrivesXCD/DVD Drives Save Changes and ExitLoad Optimal Defaults Load Fail-Safe DefaultsDiscard Changes and Exit Discard ChangesAppendix a Post Error Beep Codes Appendix B Installing the Windows Installing Windows OS for a RAID SystemInstalling Windows OS for a Non-RAID Systems Processors ChipsetMemory Capacity Sata ControllerWeight Power Supply RMC7189Chassis System Cooling

RMC 7189 specifications

The Acnodes RMC 7189 is a powerful and robust industrial computer designed to meet the demanding needs of various applications, ensuring reliable performance in harsh environments. Its rugged construction and advanced features make it a suitable choice for industries such as manufacturing, transportation, and automation.

One of the standout features of the RMC 7189 is its impressive processing capability. Equipped with an Intel Core i7 or i5 processor, it delivers high-performance computing power that can efficiently handle complex tasks and multiple applications simultaneously. The device is designed to support up to 32GB of DDR4 RAM, providing plenty of memory for even the most resource-intensive applications, ensuring smooth operation under load.

The RMC 7189 is designed with versatility in mind. It offers multiple I/O options, including COM ports, USB ports, and Ethernet interfaces, allowing for seamless connectivity with various peripherals and network devices. This flexibility is crucial for integrating the unit into existing systems, enabling it to serve as a central hub for data collection and analysis.

To enhance its durability, the RMC 7189 features a fanless design that minimizes points of failure and reduces noise, making it suitable for environments where traditional cooling methods may be impractical. The system is also resistant to dust and moisture, adhering to IP65 ratings, which makes it ideal for use in factories or outdoor settings.

In terms of storage, the RMC 7189 supports multiple options, including SSDs and HDDs, ensuring that users can choose the appropriate storage solution for their specific applications. The system also includes advanced technologies, such as RAID configurations, to provide data redundancy and protection against hardware failures.

Furthermore, the RMC 7189 is equipped with a range of expansion slots, including PCIe and Mini PCIe, allowing for integration with additional cards and modules, such as GPU for enhanced graphical processing or additional network interfaces to support various communication protocols.

The system supports a wide range of operating systems, including Windows and Linux, providing flexibility for users to choose their preferred platform. This feature, combined with its robust hardware specifications, makes the RMC 7189 a highly adaptable solution for modern industrial challenges.

In summary, the Acnodes RMC 7189 is a highly versatile and powerful industrial computer equipped with advanced features and technologies designed to perform reliably in challenging environments. With its robust construction, extensive connectivity options, and high processing capability, it stands out as an excellent choice for industries aiming to enhance their operational efficiency and data management capabilities.