Acnodes RMC 7189 user manual Fan1 ~ Fan 8 Reading

Page 83

RMC 7189

1U Rackmount System

Acnodes has leveraged this feature by assigning a temperature status to certain thermal conditions in the processor (Low, Medium and High). This makes it easier for the user to understand the CPU's temperature status, rather than by just simply seeing a temperature reading (i.e., 25oC). The CPU Temperature feature will display the CPU temperature status as detected by the BIOS:

Low - This level is considered as the 'normal' operating state. The CPU temperature is well below the CPU 'Temperature Tolerance'. The serverboard fans and CPU will run normally as configured in the BIOS (Fan Speed Control).

Medium - The processor is running warmer. This is a 'precautionary' level and generally means that there may be factors contributing to this condition, but the CPU is still within its normal operating state and below the CPU 'Temperature Tolerance'. The motherboard fans and CPU will run normally as configured in the BIOS. The fans may adjust to a faster speed depending on the Fan Speed Control settings.

User intervention: No action is required. However, consider checking the CPU fans and the chassis ventilation for blockage.

High - The processor is running hot. This is a 'caution' level since the CPU's 'Tem- perature Toler- ance' has been reached (or has been exceeded) and may activate an overheat alarm.

User intervention: If the system buzzer and Overheat LED has activated, take action immediately by checking the system fans, chassis ventilation and room temperature to correct any problems. Note: the system may shut down if it con- tinues for a long period to prevent damage to the CPU.

Notes:

1.The system may shut down if it continues for a long period to prevent damage to the CPU.

2.The information provided above is for your reference only. For more information on thermal man- agement, please refer to Intel's Web site at www.Intel.com.

System Temperature: The system temperature will be displayed (in degrees in Celsius and Fahr- enheit) as it is detected by the BIOS.

Fan1 ~ Fan 8 Reading

This feature displays the fan speed readings from fan interfaces Fan 1 through Fan 8.

 

© Copyright 2009 Acnodes, Inc.

661 Brea Canyon Rd., Suite 3

All rights reserved. Product description and product specifications

Walnut, CA 91789

are subject to change without notice. For latest product information,

tel: 909.598.7388, fax: 909.598.0218

please visit Acnodes’ web site at www.acnodes.com.

Image 83
Contents RMC Copyright 2005 Acnodes, Inc Manual Organization PrefaceBios Advanced Motherboard SetupAdvanced Chassis Setup Table of Contents System Interface Installing the System in to a RackAdvanced Motherboard Setup Advanced Chassis Setup Overview IntroductionOnboard Sata Serverboard FeaturesProcessor MemoryServer Chassis Features Cooling System Unpacking the System Choosing a Setup LocationPreparing for Setup OverviewServer Precautions Rack PrecautionsRack Mounting Considerations Identifying the Sections of the Rack Rails Installing the System into a RackInner Rails Installing the Rack RailsOuter Rails RMC Installing the Chassis into a Rack Installing the Server into a Telco Rack Checking the Components Checking the Motherboard SetupRemoving the Chassis Cover Figure Checking the Airflow Checking the Drive Bay SetupProviding Power Checking the DrivesControl Panel Buttons Reset ButtonPower Universal Information LED Control Panel LEDsNIC2 HardDrive Carrier LEDs Electrical Safety Precautions System SafetyGeneral Safety Precautions ESD Precautions Operating Precautions Handling the Motherboard PrecautionsUnpacking Processor and Heatsink InstallationInstalling an LGA1366 Processor RMC Installing the Heatsink Removing the Heatsink Connecting the Control Panel Connecting CablesConnecting Data Cables Connecting Power CablesI/O Ports Memory Support Installing Memory ModulesInstalling DIMMs RMC RMC Adding PCI Cards PCI Card InstallationServerboard Details RMC Power LED Connector DefinitionsATX Power Supply Connector Processor Power ConnectorHDD LED Universal Serial Bus Ports Power Fail LEDPower Button Chassis Intrusion Universal Serial Bus HeadersSerial Ports Fan HeadersOverheat LED Power LED/ SpeakerATX PS/2 Keyboard and PS/2 Mouse Ports LAN1/2 Ethernet Ports Power SMB I2C ConnectorUID Buttons Cmos Clear Jumper SettingsVGA Enable/Disable Explanation of JumpersSMB to PCI Express Slots LAN Enable/DisableWatch Dog Enable/Disable ME Recovery BMC/PHY ResetME Mode Select Ipmi Dedicated LAN LEDs Onboard IndicatorsLAN1/2 LEDs Sata Ports Sata Port Drive ConnectionsDriver/Tool Installation Display Screen Installing SoftwareRMC RMC Tools Required Static-Sensitive DevicesSystem Cooling Control PanelReplacing a System Fan Figure Adding a System FanSystem Fan Failure Installing a Hard Drive into a Drive Carrier Figure Drive Bay Installation/RemovalAccessing the Drive Bays Hard Drive InstallationRemoving a Hard Drive Figure DVD Drive Installation Replacing the Power Supply Power SupplyRMC Introduction Starting Bios Setup UtilityHow To Change the Configuration Data Starting the Setup Utility Main SetupSystem Memory System Time/System DateAddOn ROM Display Mode Advanced Setup ConfigurationsXboot Features Quick Boot Quiet BootHit Del Message Display Wait For F1 If ErrorRestore on AC Power Loss PS/2 Mouse SupportClock Spread Spectrum Hardware Prefetcher Available when supported by the CPUXProcessor & Clock Options CPU Ratio Intel TurboMode Technology State package limit settingActive Processor Cores Intel Eist TechnologyXAdvanced Chipset Control Patrol Scrubbing Memory ModeMemory Frequency Demand ScrubbingAltitude Inlet TemperatureTemperature Rise Air FlowSlot SXB2/SXB3 Width Active State Power ManagementNuma Support Intel I/OATXide / Floppy Configuration XPCI/PnP Configuration Uart 2 of Hermon as XSuper IO Device ConfigurationOnboard LAN Option ROM Select Load Onboard LAN1 Option ROM/Load Onboard LAN2 Option ROMXRemote Access Configuration CPU 1 Temperature/CPU 2 Temperature XHardware Health ConfigurationCPU Overheat Alarm CPU 1 Temperature/ CPU 2 Temperature/ System TemperatureFan1 ~ Fan 8 Reading Xacpi Configuration Xipmi Configuration Clear BMC System Event Log XSet LAN ConfigurationMac Address XSet PEF ConfigurationBMC Watch Dog Timer Action Gateway AddressXEvent Log Configuration Change Supervisor Password Security SettingsSupervisor Password User PasswordBoot Sector Virus Protection Change User PasswordPassword Check XHard Disk Drives Boot SettingsXBoot Device Priority Save Changes and Exit Exit OptionsXRemovable Drives XCD/DVD DrivesDiscard Changes Load Optimal DefaultsLoad Fail-Safe Defaults Discard Changes and ExitAppendix a Post Error Beep Codes Installing Windows OS for a RAID System Appendix B Installing the WindowsInstalling Windows OS for a Non-RAID Systems Sata Controller ProcessorsChipset Memory CapacitySystem Cooling WeightPower Supply RMC7189 Chassis

RMC 7189 specifications

The Acnodes RMC 7189 is a powerful and robust industrial computer designed to meet the demanding needs of various applications, ensuring reliable performance in harsh environments. Its rugged construction and advanced features make it a suitable choice for industries such as manufacturing, transportation, and automation.

One of the standout features of the RMC 7189 is its impressive processing capability. Equipped with an Intel Core i7 or i5 processor, it delivers high-performance computing power that can efficiently handle complex tasks and multiple applications simultaneously. The device is designed to support up to 32GB of DDR4 RAM, providing plenty of memory for even the most resource-intensive applications, ensuring smooth operation under load.

The RMC 7189 is designed with versatility in mind. It offers multiple I/O options, including COM ports, USB ports, and Ethernet interfaces, allowing for seamless connectivity with various peripherals and network devices. This flexibility is crucial for integrating the unit into existing systems, enabling it to serve as a central hub for data collection and analysis.

To enhance its durability, the RMC 7189 features a fanless design that minimizes points of failure and reduces noise, making it suitable for environments where traditional cooling methods may be impractical. The system is also resistant to dust and moisture, adhering to IP65 ratings, which makes it ideal for use in factories or outdoor settings.

In terms of storage, the RMC 7189 supports multiple options, including SSDs and HDDs, ensuring that users can choose the appropriate storage solution for their specific applications. The system also includes advanced technologies, such as RAID configurations, to provide data redundancy and protection against hardware failures.

Furthermore, the RMC 7189 is equipped with a range of expansion slots, including PCIe and Mini PCIe, allowing for integration with additional cards and modules, such as GPU for enhanced graphical processing or additional network interfaces to support various communication protocols.

The system supports a wide range of operating systems, including Windows and Linux, providing flexibility for users to choose their preferred platform. This feature, combined with its robust hardware specifications, makes the RMC 7189 a highly adaptable solution for modern industrial challenges.

In summary, the Acnodes RMC 7189 is a highly versatile and powerful industrial computer equipped with advanced features and technologies designed to perform reliably in challenging environments. With its robust construction, extensive connectivity options, and high processing capability, it stands out as an excellent choice for industries aiming to enhance their operational efficiency and data management capabilities.