RMC 7189
1U Rackmount System
Gateway Address
The BIOS will automatically enter the Gateway address of this machine; however it may be
Mac Address
The BIOS will automatically enter the Mac address of this machine; however it may be
XSet PEF Configuration
Set this feature to configure the Platform Event Filter (PEF). PEF interprets BMC events and performs actions based on
The following will appear if PEF Support is set to Enabled. The default is Dis- abled.
PEF Action Global Control - These are the different actions based on BMC events. The options are Alert, Power Down, Reset System, Power Cycle, OEM Action, Diagnostic Interface.
Alert Startup Delay - This feature inserts a delay during startup for PEF alerts. The options are En- abled and Disabled.
PEF Alert Startup Delay - This sets the
Startup Delay - This feature enables or disables startup delay. The options are Enabled and Dis- abled.
PEF Startup Delay - This sets the
Event Message for PEF Action - This enables of disables Event Messages for PEF action. Refer to Table 24.6 of the IPMI 1.5 Specification for more informa- tion at www.intel.com. The options are Disabled and Enabled.
BMC Watch Dog Timer Action
Allows the BMC to reset or power down the system if the operating system hangs or crashes. The options are Disabled, Reset System, Power Down, Power Cycle.
| © Copyright 2009 Acnodes, Inc. |
661 Brea Canyon Rd., Suite 3 | All rights reserved. Product description and product specifications |
Walnut, CA 91789 | are subject to change without notice. For latest product information, |
tel: 909.598.7388, fax: 909.598.0218 | please visit Acnodes’ web site at www.acnodes.com. |