Please refer to the TCP/UDP server operating mode to setup the Data Listen Port, Command Listen Port, and Data Idle Timeout.
Hangup Character: The default character is “+”. After you have connected to another serial device via
Guard Time (ms): The default value is 1000.
For example: <Guard Time> + <Guard Time> + <Guard Time> +
The following commands are available for
Table 3.1: AT Commands List
Command | Function |
ATDT<IP address> <TCP port> | “Forms a TCP connection to the specified host. |
<CR> | Ex: ATDT 192.0.55.22:5201 |
| In above example, the EKI serial device server forms |
| a raw TCP connection to the networking device |
| (192.0.55.22). The TCP port is 5201.” |
ATA <CR> | Answering an incoming call |
+++<CR> | Returns the user to the command prompt when |
| entered from the serial port during a remote host con- |
| nection. |
<LF><CR> OK <LF><CR> | Commands are executed correctly |
<LF><CR> CONNECT <LF><CR> | Connect to other device |
<LF><CR> RING ddd.ddd.ddd <LF>< Detect the connection request from other device, | |
CR> | which IP address is ddd.ddd.ddd.ddd. |
<LF><CR> DISCONNECT | Disconnect from other device |
<LF><CR> |
|
<LF><CR> ERROR <LF><CR> | Incorrect commands |
<LF><CR> FAIL <LF><CR> | If you issu an ATDT command and can not connect to |
| the device, it will response “FAIL”. |