FieldServer FS-8700-47 instruction manual Counter Change Event All Variations

Page 34

FS-8700-47 DNP 3.0 Driver Manual

 

Page 34 of 51

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Object

Variation.

Ex

 

Description

 

 

10

1*

 

Binary Output

 

 

 

10

2

 

Binary Output Status

 

 

12

0

NS

Control Descriptor - All Variations

 

 

12

1*

101a

Control Relay Output Descriptor

 

 

12

2

NS

Pattern Control Descriptor

 

 

12

3

NS

Pattern Mask

 

 

 

20

0

 

Binary Counter - All Variations

 

 

20

1*

 

32-Bit Binary Counter

 

 

20

2

 

16-Bit Binary Counter

 

 

20

3

 

32-Bit Delta Counter

 

 

20

4

 

16-Bit Binary Counter

 

 

20

5

 

32-Bit Binary Counter without Flag

 

 

20

6

 

16-Bit Binary Counter without Flag

 

 

20

7

 

32-Bit Delta Counter without Flag

 

 

20

8

 

16-Bit Delta Counter without Flag

 

 

21

0

 

Frozen Counter - All Variations

 

 

21

1*

 

32-Bit Frozen Counter

 

 

21

2

 

16-Bit Frozen Counter

 

 

21

3

 

32-Bit Frozen Delta Counter

 

 

21

4

 

16-Bit Frozen Delta Counter

 

 

21

5

 

32-Bit Frozen Counter with Time of Freeze

 

 

21

6

 

16-Bit Frozen Counter with Time of Freeze

 

 

21

7

 

32-Bit Frozen

Delta Counter with Time of Freeze

 

 

21

8

 

16-Bit Frozen

Delta Counter with Time of Freeze

 

 

21

9

 

32-Bit Frozen Counter without Flag

 

 

21

10

 

16-Bit Frozen Counter without Flag

 

 

21

11

 

32-Bit Frozen

Delta Counter without Flag

 

 

21

12

 

16-Bit Frozen

Delta Counter without Flag

 

 

22

0

101a

Counter Change Event - All Variations

 

 

22

1*

101a

32-Bit Counter Change Event without Time

 

 

22

2

101a

16-Bit Counter Change Event without Time

 

 

22

3

101a

32-Bit Delta Counter Change Event without Time

 

 

22

4

101a

16-Bit Delta Counter Change Event without Time

 

 

22

5

101a

32-Bit Counter Change Event with Time

 

 

22

6

101a

16-Bit Counter Change Event with Time

 

 

22

7

101a

32-Bit Delta Counter Change Event with Time

 

 

22

8

101a

16-Bit Delta Counter Change Event with Time

 

 

23

0

101a

Frozen Counter Event - All Variations

 

 

23

1*

101a

32-Bit Frozen Counter Event without Time

 

 

23

2

101a

16-Bit Frozen Counter Event without Time

 

 

23

3

101a

32-Bit Frozen Delta Counter Event without Time

 

 

23

4

101a

16-Bit Frozen Delta Counter Event without Time

 

 

23

5

101a

32-Bit Frozen Counter Event with Time

 

 

23

6

101a

16-Bit Frozen Counter Event with Time

 

 

23

7

101a

32-Bit Frozen Delta Counter Event with Time

 

 

23

8

101a

16-Bit Frozen Delta Counter Event with Time

 

 

30

0

 

Analog Input - All Variations

 

 

30

1*

 

32-Bit Analog Input

 

 

30

2

 

16-Bit Analog Input

 

 

30

3

 

32-Bit Analog Input without Flag

 

 

30

4

 

16-Bit Analog Input without Flag

 

 

31

0

 

Frozen Analog Input - All Variations

 

 

31

1*

 

32-Bit Frozen Analog Input

 

 

31

3

 

32-Bit Frozen Analog Input with Time of Freeze

 

FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: support@fieldserver.com

Image 34
Contents Driver Manual FS-8700-47 DNP Table of Contents FS-8700-47 DNP 3.0 Driver Manual Table of Contents DNP 3.0 Driver Description Page FS-8700-47 DNP 3.0 Driver Manual Hardware Connections Connection NotesConfiguring the FieldServer as a DNP 3.0 Driver Client Data ArraysClient Side Connection Descriptors Client Side Node DescriptorsDriver Specific Map Descriptor Parameters Timing Parameters Map Descriptor Example 1 Simple Read Map Descriptor Example 3 Simple Read Extract Value & Status Map Descriptor Example 4 Reading Class Data Map Descriptor Example 6 Read an unknown variation Configuring the FieldServer as a DNP 3.0 Driver Server Server Side Connection DescriptorsServer Side Node Descriptors Driver Specific Map Descriptor Parameters Map Descriptor Example 1 Discrete Data Map Descriptor Example 2 Class DataMap Descriptor Example 3 Class Data another example RTUMap Descriptor Example 4 Default Variation Variation zero Map Descriptor Example 5 ClassDataServingCtrl AnaInputs Map Descriptor Example 6 Unsolicited Messages Server Side Limitations Appendix A.3. DNP Objects mapped to FieldServer Data Arrays Appendix A. Advanced Topics Appendix A.1. DNP 3.0 ProtocolAppendix A.2. DNP Driver Functionality Appendix A.4. Channel Idle, Master & Slave IdleAppendix A.5. DLL Layer Functionality in the Master Appendix A.6. App Layer Functionality in the MasterAppendix A.7. Internal Indications, Object 80 and Dnpii Incoming Internal Indications BytesPage Internal Indications reported in Responses ServerIIArrayResponses to Polls for Object 80 Internal Indications Appendix A.8. DNPStats DnpstatsAppendix A.9. DNP 3.0 Data Objects Counter Change Event All Variations See notes in Appendix A.10 for function code FS-8700-47 DNP 3.0 Driver Manual Appendix A.11. Controlling the DNP 3.0 Driver’s Qualifier Appendix A.12. FieldServer DNP Node NumberAppendix A.13. DnpSubType Appendix A.15. Link ResetAppendix A.14. Communication Stats Appendix A.16. Controlling DA Offsets Appendix A.17. dnpIndexStyleAppendix A.18. Real Time Clock Synchronization DatimePage Appendix A.19. Select and Operate Page Page Appendix A.20. Multiple requests in a single poll Appendix B. Driver Error Messages Page Page Page FYI