ENGLISH
REMOTE BASS CONTROL MODULE
Before connecting the remote, it will be necessary to find a mounting location that will be easy to access for adjustment. Once you select your mounting location, you will need to run the control wire from the remote to the amplifier. To avoid possibility of induced noise from the car's electrical system (i.e. popping noises or engine noise), run the cable from the remote to the amplifier away from the car's electrical wiring.
SUBSONIC | REMOTE | PHASE | XOVER | SOURCE |
|
| |
FREQ Hz | FREQ Hz | SLAVE IN | INPUT | ||||
10 |
|
| 30 |
|
|
|
|
|
| IN | NORMAL |
| PWR \ |
| |
80 |
| OUT | 250 | SLAVE |
| PROT | L |
|
|
|
|
|
|
| |
BASS |
|
|
| L | R | - |
|
|
|
| + - | + |
| ||
BOOST |
|
|
|
|
|
|
|
30 |
| MIN |
|
|
|
| R |
125 |
| MAX |
| SPEAKER | |||
|
| LEVEL IN |
| ||||
FREQ Hz | S BOOST | GAIN | .4V - 12.2V |
| |||
|
|
|
|
|
| SLAVE OUT |
|
DIAGNOSTIC LIGHTING
The MGA11000H and MGA11500H are equipped with diagnostic lighting to display the operation status of the amplifier. The following shows the lighting mode and the description of the amplifier’s condition.
Top Light On and Blue Power LED On = Amplifier is running normally.
Top Light On and end Panel Lights are Alternating between Red and Blue = Amplifier is in thermal protection.
Top Light Blinking Slowly and Red Power light Blinking out of synch with Top Light = Over Voltage Reduce the input Voltage.
Top Light Blinking Quickly and Red Panel Light Blinking in Synch with Top Light = Short Circuit Protection.
Top Light and Red panel Light Blinking Three (3) times with a pause = Repeated shorts are detected. Remove short circuit and wait 5 minutes for this error condition to clear. The condition can also be cleared by removing the main power, for example pulling the fuse.
15