Note: not all consecutive IRQ numbers from 3 to 15 can be used; to help the selection, the Setup program displays legal IRQ numbers only.

Note: the IRQ is shared: the ports can use the same IRQ number.

VP2000 and VT100

With this option the user can enable or disable the VP2000 and VT100 functionality serial ports.

Parallel Port

Parallel Port Address

 

 

Option

Description

Note

Disabled

Disable the serial port

 

0378h

Parallel Port address selected at 378h

 

0278h

Parallel Port address selected at 278h

 

Parallel Port IRQ Number

 

 

Option

Description

Note

None

No IRQ selected for the Parallel Port

 

3

IRQ 3 selected

 

4

IRQ 4 selected

 

...

...

 

12

IRQ 12 selected

 

Note: not all consecutive IRQ numbers from 3 to 12 can be used; to help the selection, the Setup program displays legal IRQ numbers only.

Parallel DMA Channel

 

 

Option

Description

Note

None

No DMA selected for the Parallel Port

 

0

DMA Channel 0 selected

 

1

DMA Channel 1 selected

 

3

DMA Channel 3 selected

 

Parallel Port Mode

The user, according the parallel device connected to the interface, can choose The Parallel Port Mode. The default mode is Bidirectional.

Option

Description

Note

Printer

Standard mono-directional printer interface

 

Bi-directional

Bi-directional printer interface

 

PP FIFO

EPP and SPP mode

 

ECP

ECP mode

 

EPP

EPP mode

 

VP2000

 

 

With this option the user can enable or disable the VP2000 functionality on the parallel port.

Image 35
Contents COPYRIGHT 1994-2005 Eurotech S.p.A. All Rights Reserved CPU-1461EmbeddedDNA User’s ManualPC/104-Plus - CPU-1461 Module Icon Environmental safetyConventions Important features orPage Connectors Description ContentsMultifunction Connector Section ContentsAppendix Chapter 5 Watch Dog TimerChapter 6 Troubleshooting Chapter 4 The Set-up ProgramChapter 1 Product Overview Architecture Product DefinitionBIOS Flash Power SupplyChapter 2 Jumper Description Type Jumper Layout and ConfigurationDefault Jumper #Chapter 3 Connectors Description J4J5 Connectors LayoutNote in figure 2, a red square pad indicates pin 1 of each connector J14 J16 J17Page Carrier Module J4 for Multifunction and VGACPU-1461 Multifunction Connector Section ƒ Speaker The Eurotech Multifunction Adapterƒ System reset ƒ External BatterySupported CRT-VGA Video Resolutions VGA SectionIDE/DOM J5 IDE ConnectorUSB J7 for USB 2.0 Ports 5 andAuxiliary J9 Auxiliary Power ConnectorPower Power button inputThe Eurotech USB & AC97-Audio Codec Adapter J14 for USB 1.1 Ports 7 and 8 and Audio-CODECSpkPhone IN/OUT To J14 CPU Board ConnectorAux IN CD IN Aux INJ16 for USB 2.0 Ports 1to J17 for SERIAL1 and SERIAL2 Ethernet J20 for EthernetRJ45 Connector The Eurotech Ethernet TransceiverTo CPU Board NetConnector Chapter 4 The Set-up Program Press the “ESC” key to return to the items of the Main menu Select “Quit” to exit from the Setup programUse the cursor arrow keys to move the highlight to other options The follow screen will be displayed General Page The Set-up pagesFloppy disks Quick BootTime DateFloppy Controller Devices PageBoot Try Sequence Network Primary and secondary EIDEVideo Controller AC97 ControllerSerial Ports 1 and Communications PageParallel Port Mode Parallel PortVP2000 and VT100 ATAPI unit type Primary and Secondary ATAPI PageHeads PIO ModeTranslation Mode CylindersDetect Now Advanced pageLatency Time Devices PCI Advanced PageISA IRQ ISA Bus Error Handling PageError on Fixed Disks Error on KeyboardError on Video Error on Floppy DisksPage This chapter explains how to use the Watch Dog timer Chapter 5 Watch Dog TimerHow to turn the Watch Dog ON What is a Watch Dog?How to use the Watch Dog Use the System BIOS INT 52h functionsUse the following code to Enable Watch Dog Directly accessing Watch Dog I/O mapped registersHow to turn the Watch Dog OFF Use following code to refresh the Watch Dog Chapter 6 Troubleshooting CPU Module doesn’t work Common Problems and SolutionsTroubleshooting a PC/104 System Technical/Sales Assistanceftp//ftp.eurotech.it Returning For ServicePage Company Name Page Appendix Backup Battery Characteristics A.1 Electrical and Environmental SpecificationsOperating Characteristics Electrical Operating CharacteristicsMTBF Mean Time Between Failures Absolute Maximum RatingsCPU-1461 Board dimensions A.2 Mechanical DimensionsThe CPU-1461 mechanical dimensions are shown in the following picture ¾ Dimensions 90 X 96 mm 3.6”X3.8”Ethernet Adapter Dimensions USB Audio Codec Dimensions12.0 A.3 Safety SummaryMultifunction Adapter Dimensions 62.0Do Not Operate in an Explosive Atmosphere Use Caution When Exposing or Handling the CRTObserve Dangerous Procedure Warnings Ground the InstrumentLife Support Policy Disclaimer of WarrantyReliability ATAPI GlossaryB BIOS A ATAC CELLULAR G GPS NTSC M MIDIMPEG N NDISSMBus R RAMS SCSI SECAMW WAN V VGAAcronyms and Abbreviations Page ftp//ftp.eurotech.it Technical & Sales Assistancetechsupp@eurotech.it