Energizer EN1100 manual Cable Gauges

Page 9

Note:

The type of batteries you use to power your high power inverter is important. Operating a high-power inverter will routinely discharge batteries and they will require frequent recharging. Batteries used to start engines are not designed to repeatedly charge and discharge. Energizer® recommends using “deep-cycle” or “marine” rated batteries.

Cable Gauges

When connecting the inverter to a battery bank use the thickest stranded insulated copper wire available, in the shortest length practical. Recommended cable gauges are as follows:

Energizer®

Recommended Gauges

Model #

 

EN500

12AWG (3 ft. included)

EN900

8AWG (3 ft. included)

EN1100

8AWG (3 ft. included)

EN1500

4AWG (not included)

EN2000

2AWG (not included)

EN3000

0AWG (not included)

EN4000

0AWG (not included)

WARNING:

DANGER OF BATTERY EXPLOSION – INSTALL A FUSE

Battery banks can deliver very high levels of current that can vaporize metal, start fires and cause explosions. Energizer® recommends installing one ANL type fuse and fuse holder close to the positive battery bank terminal. This fuse protects the batteries from accidental DC cable shorts, which can cause batteries to explode. ANL fuses and fuse holders are available at most marine supply stores.

CAUTIONS:

Loose connections can result in a severe decrease in voltage that can cause damage to cables and insulation.

Failure to make correct polarity ( Pos, Neg ) connection between the inverter and the battery bank can result in blowing fuses in the

inverter and can permanently damage the inverter. Damage caused by reversed polarity is not covered under the Energizer® warranty.

9

Image 9
Contents Page Higher Wattage Inverter May Be Required WelcomeAppliance Cautions Getting Started Page Front Panel EN900 / EN1100 LCD DiagramRear Panel EN900 / EN1100 Determining the DC Power RequirementsSizing the Battery Bank Cable Gauges Mounting the Inverter Connecting the InverterTelevision and Audio Suggestions OperationPage Best use of Battery Power Troubleshooting Problem No Input VoltageProblem Inverter is Shut Down Problem TV does not Work Problem Low Battery Alarm on all the TimeSpecifications Description Specifications EN900Specifications EN1100 Warranty and Return Warranty by PowerBright Exclusions Return Procedure Return Material Authorization Policy