Dell SCSI 6/IR manual Bios Error Messages, Press Ctrl+C to Enable Bios

Page 40

BIOS Error Messages

Table 6-4. BIOS Error Messages

Message

Meaning

 

 

Press <Ctrl+C> to Enable BIOS

When the BIOS is disabled, you are given the option to

 

enable it by entering the configuration utility. You can

 

change the setting to Enabled in the configuration utility.

Adapter at Baseport xxxx is not responding where xxxx is the baseport of the controller

If the controller does not respond for any reason but is detected by the BIOS, it displays this warning and continues. Shut down the system and try to reseat the controller. If this message appears again, Contact Dell.

Following SAS targets are not

When the BIOS determines that previously configured

responding...

physical disks are not connected to the controller, the BIOS

 

displays this warning and continues to boot. The system

 

continues to boot. See "Physical Disk Related Issues" on

 

page 38 for troubleshooting tips.

 

 

Adapter configuration may have

Start the Configuration Utility and confirm the configuration

changed, reconfiguration is

of the SAS 6/iR controller.

recommended!

 

Press CTRL-C to run Dell SAS 6

 

Configuration Utility…

 

 

 

Initializing...

Displays while the BIOS is waiting to initialize.

 

 

SAS discovery error

Indicates that there was a discovery error reported by the

 

firmware and may be accompanied by more such messages.

 

Enter the Configuration Utility to investigate.

 

 

Integrated RAID exception detected:

The BIOS detected an exception with one or more RAID

 

virtual disk. For additional troubleshooting information, see

 

the error message "Volume (xx:yy:zzz) is

 

currently in state “STATE”.

Volume (xx:yy:zzz) is currently in state “STATE”

Lists the current state of the specified virtual disk when it is not optimal. The state may include:

INACTIVE: The virtual disk is inactive, possibly foreign, or could be in any one of the states mentioned below.

DEGRADED: The virtual disk is in a degraded state and has lost redundancy.

RESYNCING: The virtual disk is degraded and currently rebuilding.

FAILED: The virtual disk has an error and is in a failed state.

MISSING: The virtual disk is no longer present though a record of it remains.

40

Troubleshooting

Image 40
Contents User’s Guide August JM360 Contents Replacing and Rebuilding a Degraded Virtual Disk Contents Corporate Contact Details Taiwan Only Contents Safety General Safety InstructionsSafety Protecting Against Electrostatic Discharge Overview SAS 6/iR Adapter Hardware ArchitectureAbout RAID RAID TerminologyRAID Levels Integrated StripingIntegrated Mirroring Example of Integrated Mirroring RAIDOverview SAS 6/iR Features RAID 0, RAID Hardware Installation Installing the SAS 6/iR AdapterInstalling a SAS 6/iR Adapter Connecting the Cable Hardware Installation Driver Installation Creating a Driver DisketteInstalling a Windows Driver for a New SAS 6/iR Controller Boot the system using the Microsoft Windows Installation CDUpdating an Existing Windows Driver Installing the Red Hat Linux Driver Installing From the Dell Operating System MediaCreating a Driver Diskette Installing the Driver Installing the Driver Using an Update RPMInstalling the Suse Linux Enterprise Server Driver Driver Installation Upgrading the Kernel Bios Fault Code Messages SAS 6/iR BiosPost Messages Starting the Configuration Utility Configuration UtilityFunctions Performed Integrated RAID Configuration and Management Screens Navigating the Configuration UtilitySelect New Array Type Create New ArrayCreated Manage Array View ArrayExit Screen Performing Configuration Tasks Creating an Integrated Striping Virtual DiskCreating a Integrated Mirroring Virtual Disk Synchronizing a Virtual Disk Viewing Virtual Disk PropertiesActivating a Virtual Disk Hot Spare Failover Deleting a Virtual DiskReplacing and Rebuilding a Degraded Virtual Disk SAS 6/iR Bios Bios Boot Order TroubleshootingGeneral Problems Physical Disk Related Issues Other disk in the virtual diskConfiguration Utility Error Messages Bios Error Messages Press Ctrl+C to Enable BiosSpinning up the device Bios Firmware Update Utility Updating the FirmwareUpdating the Firmware Getting Help Technical Support and Customer ServiceObtaining Assistance Online Services Automated Order-Status ServiceDell Enterprise Training Problems With Your Order Before You Call Regulatory Notices Regulatory Notices Regulatory Notice Regulatory Notices Corporate Contact Details Taiwan Only Regulatory Notices Glossary AdapterDkms Nvdata Post Smart Glossary Index ESDWindows, 19 drivers, 19 updating drivers