Dell H800, H700 manual Tables, Appendix a

Page 4

Dell

 

 

 

5.3.5

 

RAID 10 (Striping over Mirrored Sets)

25

5.3.6

 

RAID 50 (Striping Across RAID 5)

26

5.3.7

 

RAID 60 (Striping Across RAID 6)

27

Appendix A.

Additional Resources

29

 

 

Tables

 

Table 1.

Comparison of PERC H700 and PERC H800 to previous PERC 6/I and PERC 6/E

5

Table 2.

6Gb/s SAS (SAS 2.0) Features

10

Table 3.

SAS Performance Details

10

Table 4.

PowerEdge Server Support with PERC H700 and PERC H800

11

Table 5.

Operating System Support with PERC H700 and PERC H800

12

Table 6.

Drive Support

12

Table 7.

PERC H700 and PERC H800 Features

13

Table 8.

RAID Level Migration

16

Table 9.

Resource Contact Information and Descriptions

29

 

 

Figures

 

Figure 1.

PERC H700 Integrated (Additional Sled for PCIe Slot)

6

Figure 2.

PERC H700 Modular

7

Figure 3.

PERC H800 Adapter

8

Figure 4.

Example of RAID 0

22

Figure 5.

Example of RAID 1 (Mirroring)

23

Figure 6.

Example of RAID 5 (Single Virtual Disk with 5 drives)

24

Figure 7.

Example of RAID 6 (Single Virtual Disk with 5 drives)

25

Figure 8.

Example of RAID 10 (1 + 0)

26

Figure 9.

Example of RAID 50 (5 + 0)

27

Figure 10.

Example of RAID 60 (6 + 0)

28

DELL PERC H700 and H800 Technical Guide

4

Image 4
Contents Dell PowerEdge RAID Controller Cards March Table of Contents Tables Appendix aProduct Comparison OverviewPerc H700 Overview Perc H700 Integrated Additional Sled for PCIe SlotPerc H800 Overview Perc H700 ModularPerc H800 Adapter New Features 6Gb/s SAS SAS 2.0 OverviewGb/s SAS SAS 2.0 Features 1 6Gb/s SAS Performance Benefit over 3Gb/s SAS2 6Gb/s SAS Expectation SAS Performance DetailsDell PowerEdge Server Support PowerEdge Server Support with Perc H700 and Perc H800Product Support Management Software SupportOperating System Support with Perc H700 and Perc H800 Drive SupportDrive Support Product Overview Perc H700 and Perc H800 FeaturesPerc H700 and Perc H800 Overview Power Management RAID Level CacheCade Reconfiguring Virtual DisksCut-Through IO Fault-Tolerance Features RAID Level MigrationNon-Volatile Cache Using Replace Member and Revertible Hot SparesAutomatic Replace Member with Predicted Failure Physical Disk Hot Swapping Battery Back-up of Controller CacheEnclosure Affinity Configuring and Managing Secured RAID Disk RoamingDisk Migration Perc H700 and H800 Security Key and RAID ManagementVirtual Disk Write Cache Policies Virtual Disk Read Cache PoliciesRAID 0 Striped Virtual Disk without Fault Tolerance RAID OverviewAbout RAID Advantages of RAIDRAID 1 Mirroring Example of RAID Advantages of RAIDRAID 5 Striping With Distributed Parity Example of RAID 1 MirroringRAID 6 Striping With Dual Distributed Parity DriveRAID 10 Striping over Mirrored Sets Example of RAID 6 Single Virtual Disk with 5 drivesRAID 50 Striping Across RAID Disadvantages of RAIDRAID 60 Striping Across RAID Example of RAID 50 5 + Advantages of RAIDExample of RAID 60 6 + Advantages of RAID Appendix A. Additional Resources Resource Contact Information and Descriptions